Many NDT inspectors wonder whether to buy a corrosion gauge or a flaw detector, or both. The answer depends on the application: the two instruments use the same ultrasonic physics but are optimised for different tasks. A corrosion gauge is designed to measure thickness accurately and document degradation over time; a flaw detector is designed to locate, size and classify internal discontinuities in materials.

What a corrosion gauge does
A corrosion gauge (thickness gauge) is an instrument dedicated to measuring the remaining thickness of metal walls, typically to monitor the progress of corrosion. The Dakota NDT models of the CX, ZX, MX, CMX series are optimised for this purpose with specific features.
- Dual element probes: two piezoelectric crystals (separate transmitter and receiver) that allow reliable measurements even on corroded and irregular surfaces
- Echo-Echo ThruPaint™ mode: ignores coatings up to 2 mm and measures only the thickness of the metal
- High-speed scan mode (up to 250 readings/sec on the MX and CMX models) for mapping large surfaces quickly
- Data logger structured for repetitive inspections with grids and batches
- Hi/Lo alarms to flag automatically any thickness below the critical threshold
- Differential mode to compare the current measurement with a reference value
- Compliance with inspection standards: ASTM E 797, EN 14127, EN 15317

Need help choosing the right product?
What a flaw detector does

A flaw detector is an instrument that displays the ultrasonic waveform as an A-Scan and lets the operator identify, measure and classify internal discontinuities: cracks, inclusions, porosity, delaminations. The Dakota FX70-DL, FX71-DL and FX81-DL models are designed for this purpose with specific functions.
- Sizing toolkit: DAC, AWS, TCG, DGS for sizing defects according to recognised standards
- Angle shear wave probes (in addition to single element probes) for weld inspection
- PRF adjustable up to 2000 Hz for fast scanning
- 3 detection modes: Z-Cross, Flank, Peak — to choose the measurement point on the echo
- TCG (Time Corrected Gain): automatically compensates for attenuation with depth
- A-Scan and B-Scan display for graphical interpretation of the signal
- EN 12668-1 compliance for flaw detectors
- Handling of wedges and angle transducers for the inspection of welded joints
The key practical differences
| Aspect | Corrosion gauge | Flaw detector |
|---|---|---|
| Primary purpose | Measure remaining thickness | Locate and size defects |
| Typical probes | Dual element, corrosion probes | Single element and angle shear wave |
| Display | Numeric + B-Scan | Detailed A-Scan + B-Scan |
| Sizing toolkit | — | DAC, AWS, TCG, DGS |
| Typical scan mode | 250 readings/sec | PRF up to 2000 Hz |
| Data logger | Yes, structured in grids | Yes, with A/B-Scan images |
| Reference standard | ASTM E 797, EN 14127 | EN 12668-1 |
| Weld inspection | Not suitable | Typical application |
| Corrosion monitoring | Typical application | Possible but oversized |
When you need both

There are situations in which a company or an inspector needs both instruments in their kit:
- Maintenance of process plants: the corrosion gauge is used for periodic thickness checks on piping and tanks (API 570, API 653); the flaw detector is used to inspect welds during repairs or modifications
- New construction and acceptance testing: the flaw detector is mandatory for weld quality control (AWS D1.1, EN ISO 17640); the corrosion gauge is used for baseline dimensional checks
- NDT inspection contractors: anyone offering services must be able to respond to varied requests from customers
- Aerospace and composites: detecting delaminations calls for a flaw detector, while thickness checks on machined components call for a precision gauge
Dakota NDT hybrid alternatives
The FX70-DL, FX71-DL and FX81-DL models of the FX series combine both functions in a single instrument: they are fully fledged flaw detectors, but can be switched to thickness gauge mode to measure material and coating thickness simultaneously (Pulse-Echo Coating Mode). They are a sound solution when working in mixed contexts, but they do not replace the specialisation of a dedicated gauge for intensive thickness mapping campaigns.
To assess with us the configuration best suited to Your needs — dedicated gauge, dedicated detector or hybrid solution — contact our technical office.