Home —» Products —» Bolt Tension Monitors —» Dakota MultiMax – Remote bolt tension monitoring, 4 channels

Dakota MultiMax – Remote bolt tension monitoring, 4 channels

Dakota MultiMax, 4-channel bolt tension monitor with transducers

The Dakota MultiMax is a 4-channel bolt tension monitor that measures elongation by the ultrasonic method continuously and remotely, with automatic temperature compensation, for joints that have to stay under control over time.

  • ✓ 4 channels multiplexed, stackable modules to monitor several bolts
  • ✓ Measuring range 25.4 mm – 15.2 m, resolution ± 0.0001 mm
  • ✓ Automatic temperature compensation in real time
  • ✓ Measurement of elongation, load, stress and % strain
  • ✓ Recording from six times a minute to once a month, 4 GB SD memory
  • ✓ Glue-On transducers for permanent installation
  • ✓ IP65 aluminium housing, 383 g, −10 / +60 °C
  • ✓ Compliant with ASTM E1685-20, NIST-traceable calibration

The tightening of a bolt is not a figure you acquire only once. A flanged joint loses preload through settling, through thermal cycles, through vibration: at assembly the torque was right, six months later it may no longer be. The problem, in the field, is that going back to measure bolt by bolt on a line at height or on a wind turbine foundation costs plant downtime and hours of specialised personnel.

The MultiMax answers this situation by staying installed on the plant. The transducers, permanently glued to the bolt head, do not move between one reading and the next; the instrument switches automatically between the four channels and records the value at the rate you decide. The built-in temperature probe corrects the reading in real time, so that thermal expansion is not mistaken for a loss of tension.

The result is not a measurement but a history: the preload curve over time, from which you can see whether a joint is giving way long before the failure becomes a breakdown. Below you will find its positioning in the range, the full specifications taken from the official datasheet and the typical application cases.

Positioning in the range

The MultiMax is not an alternative to the portable monitors: it answers a different question, namely how is the tightening now, and how was it last week.

InstrumentUseWhat it solves
BT1-DLportablefield measurement, bolt by bolt
BT2-DLbenchtopworkshop and test room
MultiMaxfixed installationcontinuous, unattended monitoring of several bolts

When to choose the MultiMax

Dakota NDT transducers for bolt tension monitors
  • Critical joints whose behaviour has to be documented over time, not only at assembly
  • Bolts in hard-to-reach positions, where going back to measure by hand is costly or dangerous
  • Plants subject to thermal cycles or vibration, where preload can drop between one check and the next
  • The need to monitor more than 4 bolts: the modules stack
  • Permanent installation of the transducers, with the Glue-On option

Documentation download

Official Dakota NDT technical documentation. The file opens in a new tab.

Scarica il PDFDatasheet MultiMax Bolt Tension Monitor
Manufacturer official datasheet — PDF, 2 pages, in English

Main features

Continuous monitoring

  • 4 multiplexed channels with automatic switching between the bolts
  • Stackable modules to increase the total number of channels
  • Automatic recording at a rate from six times a minute to once a month
  • Formats .sm2 and CSV, recorded automatically or manually

Temperature compensation

The MultiMax has a built-in temperature probe with automatic compensation in real time. This is the condition for prolonged monitoring to make sense: without compensation, a thermal variation of the plant would be read as a variation in bolt tension.

Glue-On transducers

Permanent bonding removes positioning errors and shifts between one measurement and the next: once glued, the measuring point no longer changes. It is the natural choice for fixed installation and remote monitoring.

Measured quantities

  • Time in nanoseconds
  • Elongation — change in length in inches or millimetres
  • Load — force applied in pounds, KIP or MPa
  • Stress — force per unit area
  • % Strain — ratio between elongation and effective length

Control and display

PC management of Dakota NDT ultrasonic measurement data

The MultiMax has no keypad: it is controlled entirely from the PC through the MultiUI software, which configures its channels and manages the stacked modules.

The display includes A-scan with RF waveform, a large numeric readout and a repeatability bar graph. The Auto Set function automates detection, scope and display settings for each bolt.

Full technical specifications

Data taken from the manufacturer’s official datasheet.

ParameterValue
Measuring modePulse-Echo (P-E)
Measuring range25.4 mm – 15.2 m (1 in – 50 ft), depending on material type and homogeneity
Velocity range1250 – 13,995 m/s
Resolution± 0.0001 mm
DetectionZero Crossing
Calibrationautomatic or fixed; 1- or 2-point zeroing
Channels4, multiplexed; stackable modules
Measuring gatesingle gate with adjustable threshold and polarity
Timingprecision TCXO, 100 MHz 8-bit digitizer
Pulser typeSquare Wave
Pulser voltage100, 150 and 200 V selectable
Pulse widthSpike, Thin and Wide, 80 – 400 ns
Damping100 ohm
Frequency bandbroadband 1.8 – 19 MHz (−3 dB)
Horizontal linearity± 0.4% FSW
Vertical linearity± 1% FSH
Amplifier linearity± 1 dB
Delay0 – 25,400 mm at steel velocity
Transducerssingle element, 1 – 10 MHz, diameters 1/8″ – 1″; Glue-On option
Transducer connectors4 × Lemo 00 on the instrument
Temperature sensorLemo 5 pin, automatic compensation
Memoryinternal 4 GB SD, fixed grid format
PC interfacedirect USB-C 1.1, Windows software
Keypadnone: control from PC
Units of measurementinches, millimetres or time (µs); °C or °F
Bolt materialspreset list or custom values
Power supplymains: USB to PC or AC adapter
Operating temperature−10 / +60 °C
ProtectionIP65
Housingextruded aluminium, nickel-plated aluminium end caps
Weight383 g (13.5 oz) with batteries
Dimensions76.2 × 165 × 38.1 mm

Typical applications

Pressure flanges

Preload control on flanged joints is the most direct use case: see Tightening pressure flanges: why a torque wrench is not enough and the reference standard in ASME PCC-1.

Wind turbines

Foundation and tower joint bolts, in awkward positions and subject to load cycles: they are the natural candidate for continuous monitoring. Further reading: Bolt tension in wind turbines.

Process plants and machinery

Compressors, pumps and rotating machines, where the loosening of a tie rod shows up only once the damage has already occurred. Continuous monitoring anticipates unplanned downtime.

Comparison with the portable monitors

FeatureMultiMaxBT1-DLBT2-DL
Usefixed installationportable in the fieldbenchtop
Continuous unattended measurementyesnono
Simultaneous channels4, expandable11
Controlfrom PC onlyon boardon board
Temperature compensationautomaticsee datasheetsee datasheet

For a comparison between the two portables: Dakota BT1-DL vs BT2-DL.

Standards and certifications

  • ASTM E1685-20 — standard cited by the manufacturer for the ultrasonic measurement of bolt elongation
  • Factory calibration NIST-traceable and compliant with MIL-STD-45662A
  • CE and FCC ICES certifications
  • 2-year limited warranty · made in the USA

On the regulatory framework for controlled tightening: ASME PCC-1.

Frequently asked questions

How many bolts can I monitor with one MultiMax?

Four per module, thanks to the 4 multiplexed channels. Several modules can be stacked and managed together from the MultiUI software, increasing the total number of monitored channels.

Can the MultiMax be used as a portable instrument?

It is not designed for that. It has no keypad or on-board controls and requires a connected PC: it is an instrument for fixed installation. For field measurement bolt by bolt there are the BT1-DL and BT2-DL monitors.

How often does it record the measurements?

The rate can be set from six times a minute to once a month, depending on the dynamics of the phenomenon being followed. The data is stored on the internal 4 GB SD memory.

Does the temperature variation distort the measurement?

It is the main risk of any prolonged monitoring, and that is why the MultiMax has a built-in temperature probe with automatic compensation in real time: the reading stays referred to the actual bolt tension and not to thermal expansion.

Are the Glue-On transducers removable?

The Glue-On option is intended for permanent installation on the bolt, precisely to eliminate repositioning errors between one measurement and the next. For non-permanent applications, transducers with a traditional connection are available.

For an assessment of the application, the choice of transducers and the sizing of the number of channels, contact our technical department.

Further information and contacts

Systems division and sensor integration partner : www.roder.it
More information about RODER SRL : about us
Contact for general information : info@roder.it
Contact for information about these products : info@roder.it


The information contained on this web page is provided for information purposes only. Although it has been compiled with the utmost care, it does not constitute a contractual offer or a binding commitment to supply. It may contain transcription, translation or typographical errors. For precise and up-to-date information, please contact our company directly.

Some images on this website have been intentionally generated using Artificial Intelligence (AI). This is because, for many applications and projects, it is not possible to disclose photographs of the installation or of the actual system due to confidentiality agreements, confidentiality clauses and non-disclosure agreements (NDAs).