News
-

1-point vs 2-point calibration: the differences and when to use each
Calibrating the ultrasonic instrument is fundamental to the accuracy of the readings. 1-point calibration corrects the offset and is quick; 2-point calibration also corrects the gain, for accurate readings across wide ranges. A guide to the procedures, to choosing between them and to good operating practice.
-

What PECT mode is and when it becomes indispensable in corrosion measurement
PECT mode (Pulse-Echo Coating Through) on the Dakota CMX instruments measures the thickness of the coating and of the metal beneath it at the same time, in a single reading, while still detecting pitting and flaws. Essential for inspecting corrosion under coating, tanks and protected piping.
-

Data logger vs manual recording: why NDT readings should be archived
The internal data logger of an ultrasonic instrument is now a requirement for professional inspections. It removes transcription errors, saves the A-Scan waveform, makes trend analysis possible and automates reporting with DakMaster™. Every Dakota “-DL” instrument has a data logger of 4 GB or more.
-

How to choose the right ultrasonic transducer for every application
The choice of the ultrasonic transducer is crucial to the quality of the measurement. A complete guide to Dakota NDT probes: dual element for corrosion, single element for precision, delay line for thin thicknesses, angled shear wave for welds, high temperature, underwater and low frequency for difficult materials.
-

Thickness measurement in goods-inwards quality control
Ultrasonic thickness measurement in goods-inwards quality control verifies that plate, tube and section steel complies with the tolerances declared by the supplier. A guide to the procedure, to choosing between the Dakota CX and CX8-DL instruments and to integration with ISO 9001, EN 9100 and IATF 16949 quality systems.
-

Echo-Echo and ThruPaint™: measuring thickness through paint and coatings
Echo-Echo mode (marketed as ThruPaint™ on Dakota instruments) measures the thickness of the metal while ignoring coatings up to 2 mm. There is no need to strip the paint for the inspection, and the protection stays intact. Available on the CX4, CX8-DL, MX, CMX and FX from Dakota NDT.
-

Uniform corrosion monitoring: methods, instruments and standards
Uniform corrosion monitoring on piping and tanks relies on repeatable ultrasonic measurements at fixed Condition Monitoring Locations, archived over time to calculate the corrosion rate and the remaining life. Methodological guide, choice of Dakota CMX and CX8-DL instruments, API 570 and 653 regulatory framework.
-

How to improve results on difficult materials with an ultrasonic gauge
Cast irons, composites, thick plastics and coarse-grained alloys show attenuation and grain noise that make standard ultrasonic measurement difficult. A guide to the technical strategies for obtaining reliable results: instrument selection (PMX4-DL, CMX, FX), probe, couplant, calibration and A-Scan validation.
-

How to measure the thickness of tubes and piping with an ultrasonic gauge
A practical guide to ultrasonic thickness measurement on tubes and piping in carbon steel, stainless steel and plastic. Measurement principle, calibration, probe selection, grid mapping to API 570, typical problems and the Dakota NDT instruments recommended for each type of application.