Home —» News —» Ultrasonic weld inspection to AWS D1.1 with the Dakota FX70-DL

Ultrasonic weld inspection to AWS D1.1 with the Dakota FX70-DL

Dakota NDT FX70 Flaw Detector Powerful for ultrasonic flaw and crack measurement

A practical guide to using the Dakota FX70-DL for ultrasonic inspection of structural welds to AWS D1.1. The flaw detector includes the AWS toolkit for automatic calculation of the indication rating, DAC, DGS, TCG. EN 12668-1 compliant, NIST-MIL-STD calibration, 4 GB memory, download to DakMaster™.

Ultrasonic inspection of structural welds to AWS D1.1 is the reference procedure in steel construction: bridges, buildings, offshore platforms, industrial plants. The Dakota FX70-DL is a portable flaw detector compliant with EN 12668-1 that natively includes the AWS toolkit for automatic flaw sizing according to the criteria of AWS D1.1 Clause 6. This article is a guide to the practical use of the FX70-DL for structural weld inspection.

Dakota FX70-DL for AWS D1.1 weld inspection

Why the FX70-DL for welds

According to the official Dakota NDT data sheet, the FX70-DL and its twin, the FX71-DL (formerly DFX-7 and DFX-7+), include all the toolkits required for weld inspection:

  • AWS: automatic flaw sizing to AWS D1.1
  • DAC: Distance Amplitude Correction, up to 8 points with -2, -6, -10 dB reference curves
  • DGS-AVG: European sizing method based on theoretical curves
  • TCG: Time Corrected Gain, automatically compensates for attenuation
  • TRIG: trigonometric display for beam path, depth, surface distance with correction for curved surfaces
  • Toolkits compatible with angle beam transducers and wedges

Other technical features relevant to weld inspection:

  • AMOLED VGA 320×240 display readable in direct light
  • PRF adjustable from 8 to 2000 Hz
  • 3 selectable detection modes: Z-Cross, Flank, Peak
  • 4 GB memory for storing readings with A-Scan and B-Scan
  • Download to DakMaster™ via USB
  • EN 12668-1 compliance
  • Calibration traceable to NIST & MIL-STD-45662A

Standard AWS D1.1 inspection procedure

Diagram of ultrasonic weld inspection with angle probes
  1. Surface preparation: cleaning of the scanning area on both sides of the weld, removal of weld spatter and oxides
  2. Calibration on the IIW block (per AWS): check of horizontal linearity, vertical linearity, the index point of the angle probe and the refraction angle
  3. Setting the reference level on the FX70-DL on the echo from a reference reflector (∅ 2.4 mm side-drilled hole or equivalent)
  4. Scanning the weld: zig-zag pattern on both sides of the bead, with an angle suited to the thickness (45° for greater thicknesses, 60°-70° for smaller thicknesses)
  5. Locating the indications: the TRIG toolkit automatically displays the depth, surface distance and beam path of the echo position
  6. Calculating the indication rating with the AWS toolkit: the instrument automatically calculates d = a − b − c
  7. Comparison with Table 6.2 of AWS D1.1: classification of the indication as acceptable, to be recorded or to be rejected
  8. Storage: reading, A-Scan, position and classification saved in the FX70-DL data logger

The AWS toolkit built into the FX70-DL

AWS D1.1 structural weld inspection

AWS D1.1 defines the indication rating d as:

d = a − b − c

where:

  • a = indication level in dB (echo amplitude of the actual indication)
  • b = reference level in dB (echo amplitude of the reference reflector)
  • c = attenuation factor in dB (attenuation factor as a function of the sound path)

The AWS toolkit of the Dakota FX70-DL automatically calculates all these values as the operator acquires the echoes. The indication rating is compared with the acceptance criteria of Table 6.2 of AWS D1.1, which distinguish:

  • Class A — large indications (rejected)
  • Class B — medium indications (rejected if they exceed certain criteria)
  • Class C — small indications (acceptable with recording)
  • Class D — minor indications (disregarded)

Typical applications

  • Heavy steelwork: I-beams, columns, welded nodes of steel structures
  • Road and railway bridges: welds in cruciform joints, T-joints, butt welds
  • Storage tanks: vertical and circumferential shell welds to API 620/650
  • Pressure vessels: welds in shell courses and heads (ASME VIII Div. 1 and 2)
  • Offshore jackets: tubular K, Y and T nodes
  • Heavy machinery components: structures of cranes, graders, lifts

Reporting

At the end of the inspection, all the data stored in the FX70-DL is downloaded via DakMaster™ to produce the standard AWS D1.1 report. The A-Scan waveforms of the classifiable indications are attached as evidence, and the output format is compatible with the documentation requirements of the AWS Certified Welding Inspector in charge of the campaign.


For configuration of the Dakota FX70-DL according to your internal AWS D1.1 procedures and for hands-on training of UT personnel, contact our technical department.