Home —» NDT Technologies and Standards —» Measurement data management —» USB and Bluetooth data download

USB and Bluetooth data download

Ultrasonic instrument transmitting measurement data to the computer

As long as the readings stay in the instrument’s memory they belong to one person. The transfer to the computer is the moment they become an asset of the organisation.

  • USB cable connection for transfer at the end of the campaign
  • Wireless transmission on the models equipped with it
  • Batches and grids arriving already structured on the computer
  • DakMaster software as the common interface to the instruments

The internal memory of a thickness gauge is a temporary archive. It serves to collect readings during the campaign, not to preserve them: an instrument can be lost, cleared by mistake or assigned to another team, and with it the only copy of the work done would disappear. For this reason the transfer to the computer is not an optional step but the natural conclusion of the inspection.

The transfer does not move only the values. The structure of the batch or the grid, the identifier of each point and, on instruments with A-Scan display, the waveform associated with the reading all pass across as well. It is this whole that makes the data verifiable years later: without the structure, a list of numbers allows neither comparison nor review.

There are two available routes. The USB cable connection is the ordinary end-of-day solution: the instrument is connected to the computer and the batches are imported into the management software. Wireless transmission, present on the models that provide for it, instead moves the transfer into the field, and makes it possible for readings to reach an external device while the inspection is still under way.

The two routes compared

AspectWhat applies
Cable connectionTransfer at the end of the campaign, with the instrument connected to the computer
Wireless transmissionAvailable on the models that provide for it, usable in the field
What is transferredValues, batch structure, point identifiers, waveforms
DestinationArchive organised by project in the data management software
When to do itAt the end of each campaign, before the instrument is used again

What happens on the computer

Instrument with data logger during a measurement on a mechanical part

Dakota NDT distributes its software free of charge. DakMaster imports the readings, organises them by project, analyses them with statistics and charts and produces the inspection report; it is the common interface to both thickness gauges and flaw detectors, and this avoids having to manage a different program for every instrument in the fleet.

The transfer does not only concern the direction from instrument to computer. Configuration files can be sent from the computer to the instrument, that is the measurement settings and the batch structures prepared in advance: in this way several operators go into the field with exactly the same set-up, and campaigns remain comparable even when the team changes.

Recommended items

ItemUse
DakMasterImport of readings, archive by project and reporting
MultiUIConfiguration and monitoring of the MultiMax system
Dakota CX8-DLThickness gauge with data logger and B-Scan to download at the end of the campaign
Dakota PMX3-DLPrecision measurements with A-Scan and waveform storage

Frequently asked questions

Is Dakota NDT software chargeable?

No, the manufacturer distributes it free of charge. DakMaster is the common interface to both thickness gauges and flaw detectors, and covers data import, analysis and report production.

Is anything lost in the transfer compared with what was recorded?

No: along with the values, the structure of the batch or the grid and the identifier of each point pass across, and on instruments with A-Scan display the waveform associated with the reading as well.

Can settings be sent from the computer to the instrument?

Yes. Configuration files prepared on the computer can be transferred to the instrument, so that several operators work with the same measurement set-up and campaigns remain comparable.

Back to Management of measurement data or write to us from the Contact page.

Further information and contacts

Systems division and sensor integration partner : www.roder.it
More information about RODER SRL : about us
Contact for general information : info@roder.it
Contact for information about these products : info@roder.it


The information contained on this web page is provided for information purposes only. Although it has been compiled with the utmost care, it does not constitute a contractual offer or a binding commitment to supply. It may contain transcription, translation or typographical errors. For precise and up-to-date information, please contact our company directly.

Some images on this website have been intentionally generated using Artificial Intelligence (AI). This is because, for many applications and projects, it is not possible to disclose photographs of the installation or of the actual system due to confidentiality agreements, confidentiality clauses and non-disclosure agreements (NDAs).