{"id":3519,"date":"2026-09-07T15:06:32","date_gmt":"2026-09-07T15:06:32","guid":{"rendered":"https:\/\/ultrasuonindt.it\/trazabilidad-nist-y-mil-std-45662a\/"},"modified":"2026-09-13T02:16:00","modified_gmt":"2026-09-13T02:16:00","slug":"trazabilidad-nist-y-mil-std-45662a","status":"publish","type":"page","link":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/","title":{"rendered":"Trazabilidad NIST y MIL-STD-45662A"},"content":{"rendered":"\n<div class=\"wp-block-columns are-vertically-aligned-top is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:36%\">\n<figure class=\"wp-block-image size-large has-custom-border\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"700\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?resize=700%2C700&#038;ssl=1\" alt=\"Bloques de calibraci&#xF3;n con certificado para medidores de espesor por ultrasonidos\" class=\"wp-image-1583\" style=\"border-color:#000000;border-width:1px;border-radius:15px\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?w=700&amp;ssl=1 700w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?resize=150%2C150&amp;ssl=1 150w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:4%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:60%\">\n<div class=\"wp-block-group has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:6px;border-bottom-right-radius:6px;border-left-color:#225f78;border-left-width:6px;background-color:#ebf1f4;padding-top:24px;padding-right:28px;padding-bottom:24px;padding-left:28px\">\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#225f78;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.408), 18px);font-style:italic;font-weight:400;line-height:1.6\">La trazabilidad es una propiedad del resultado de medida, no un sello del equipo. Y la norma militar que muchos pliegos siguen citando est\u00e1 anulada desde hace tiempo. <\/p>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\" style=\"list-style:none;padding-left:0px;line-height:1.6\">\n<li style=\"list-style:none\"><strong style=\"color:#225f78\">\u2713<\/strong> Definici\u00f3n del VIM: cadena documentada e ininterrumpida de calibraciones<\/li>\n\n\n\n<li style=\"list-style:none\"><strong style=\"color:#225f78\">\u2713<\/strong> El NIST no certifica la trazabilidad de medidas que no realiza \u00e9l mismo<\/li>\n\n\n\n<li style=\"list-style:none\"><strong style=\"color:#225f78\">\u2713<\/strong> MIL-STD-45662A, Rev. A de 1988: anulada<\/li>\n\n\n\n<li style=\"list-style:none\"><strong style=\"color:#225f78\">\u2713<\/strong> Referencias actuales: ANSI\/NCSL Z540-1 (despu\u00e9s Z540.3), ISO 10012, ISO\/IEC 17025<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\">En los certificados de calibraci\u00f3n aparece a menudo la f\u00f3rmula \u00abtrazable NIST\u00bb, y otras tantas veces los pliegos remiten a MIL-STD-45662A. Ambas expresiones merecen una comprobaci\u00f3n, porque ninguna significa hoy lo que quienes las escriben suelen entender. <\/p>\n\n<p class=\"wp-block-paragraph\">Partamos de la definici\u00f3n. Seg\u00fan el VIM, el vocabulario internacional de metrolog\u00eda, la trazabilidad metrol\u00f3gica es la <em>\u201cproperty of a measurement result whereby the result can be related to a reference through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty\u201d<\/em>: la \u00abpropiedad de un resultado de medida por la cual el resultado puede relacionarse con una referencia mediante una cadena documentada e ininterrumpida de calibraciones, cada una de las cuales contribuye a la incertidumbre de medida\u00bb. <\/p>\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-cover is-light popmake-4066 popmake-739\" style=\"border-width:1px;min-height:250px;aspect-ratio:unset;\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"250\" class=\"wp-block-cover__image-background wp-image-727 size-full\" alt=\"\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=1200%2C250&#038;ssl=1\" data-object-fit=\"cover\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?w=1200&amp;ssl=1 1200w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=300%2C63&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=1024%2C213&amp;ssl=1 1024w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=768%2C160&amp;ssl=1 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-30 has-background-dim\" style=\"background-color:#d3d6dc\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-15701bb7 wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-right has-ti-fg-color is-style-default has-luminous-vivid-amber-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"font-size:clamp(21.536px, 1.346rem + ((1vw - 3.2px) * 1.374), 35px);\"><strong>\u00bfNecesita ayuda para elegir el producto adecuado?<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-b507c051 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-4066 popmake-739\"><a class=\"wp-block-button__link has-ti-accent-color has-cyan-bluish-gray-background-color has-text-color has-background has-link-color wp-element-button\">Cont\u00e1ctenos<\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"wp-block-paragraph\">El propio NIST es expl\u00edcito en dos puntos. El primero: <em>\u201cNIST does not define, specify, assure, or certify metrological traceability of the results of measurements except those that NIST itself provides\u201d<\/em>, es decir, \u00abel NIST no define, especifica, garantiza ni certifica la trazabilidad metrol\u00f3gica de los resultados de medida, salvo los que el propio NIST proporciona\u00bb. El segundo: <em>\u201ctraceability is the property of the result of a measurement, not of an instrument or calibration report or laboratory\u201d<\/em>, esto es, \u00abla trazabilidad es una propiedad del resultado de una medida, no de un equipo, de un informe de calibraci\u00f3n o de un laboratorio\u00bb.  <\/p>\n\n<h2 class=\"wp-block-heading\">MIL-STD-45662A: qu\u00e9 ha ocurrido<\/h2>\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th style=\"background-color:#225f78;color:#ffffff;padding:10px\">Elemento<\/th><th style=\"background-color:#225f78;color:#ffffff;padding:10px\">Dato<\/th><\/tr><\/thead><tbody><tr><td>Documento<\/td><td>MILITARY STANDARD: CALIBRATION SYSTEM REQUIREMENTS, DoD<\/td><\/tr><tr><td>Revisi\u00f3n<\/td><td>Rev. A, 1 de agosto de 1988<\/td><\/tr><tr><td>Estado<\/td><td>Anulada, marcada como sustituida por ISO 10012-1 y ANSI Z540-1<\/td><\/tr><tr><td>Fecha de sustituci\u00f3n<\/td><td>Indicaci\u00f3n del 20 de enero de 1995, recogida por una \u00fanica fuente<\/td><\/tr><tr><td>Referencias actuales<\/td><td>ANSI\/NCSL Z540-1 (despu\u00e9s Z540.3), ISO 10012, ISO\/IEC 17025<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">Qu\u00e9 escribir hoy en un pliego<\/h2>\n\n<div class=\"wp-block-columns are-vertically-aligned-top is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:36%\">\n<figure class=\"wp-block-image size-large has-custom-border\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"960\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?resize=960%2C960&#038;ssl=1\" alt=\"Procedimiento de calibraci&#xF3;n y verificaci&#xF3;n de un equipo de ultrasonidos\" class=\"wp-image-984\" style=\"border-color:#000000;border-width:1px;border-radius:15px\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?w=960&amp;ssl=1 960w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?resize=768%2C768&amp;ssl=1 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:4%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:60%\">\n<p class=\"wp-block-paragraph\">Consideramos correcto decirlo abiertamente: <strong>MIL-STD-45662A est\u00e1 anulada<\/strong>. La revisi\u00f3n A lleva fecha de 1 de agosto de 1988 y est\u00e1 marcada como sustituida por ISO 10012-1 y ANSI Z540-1; la indicaci\u00f3n de sustituci\u00f3n del 20 de enero de 1995 procede de una sola fuente y la recogemos como tal, no como dato cierto. Seguir cit\u00e1ndola en una especificaci\u00f3n de compra significa exigir conformidad con un documento que ya no est\u00e1 en vigor.  <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Las referencias actuales para los sistemas de calibraci\u00f3n son ANSI\/NCSL Z540-1 y la posterior Z540.3, ISO 10012 y, para la competencia de los laboratorios de ensayo y calibraci\u00f3n, ISO\/IEC 17025. Es a estas a las que conviene remitir cuando se redacta un requisito nuevo. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En cuanto a la f\u00f3rmula \u00abtrazable NIST\u00bb, la consecuencia pr\u00e1ctica de las dos declaraciones citadas m\u00e1s arriba es sencilla: lo que hace defendible un certificado no es el nombre de un instituto impreso en la portada, sino la cadena documentada de calibraciones y la incertidumbre declarada. Nuestro servicio se describe en la p\u00e1gina <a href=\"https:\/\/ultrasuonindt.it\/es\/soporte\/calibrazione-e-taratura\/\">Calibraci\u00f3n y ajuste<\/a>. <\/p>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Instrumentos recomendados<\/h2>\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th style=\"background-color:#225f78;color:#ffffff;padding:10px\">Elemento<\/th><th style=\"background-color:#225f78;color:#ffffff;padding:10px\">Uso<\/th><\/tr><\/thead><tbody><tr><td><a href=\"https:\/\/ultrasuonindt.it\/prodotti\/sonde-e-accessori\/blocchetti-calibrazione\/\">Bloques de calibraci\u00f3n<\/a><\/td><td>Referencia f\u00edsica para la verificaci\u00f3n de la cadena de medida<\/td><\/tr><tr><td><a href=\"https:\/\/ultrasuonindt.it\/prodotti\/sonde-e-accessori\/trasduttori-spessimetri-precisione\/\">Palpadores de precisi\u00f3n<\/a><\/td><td>Palpadores empleados en las verificaciones de alta exactitud<\/td><\/tr><tr><td><a href=\"https:\/\/ultrasuonindt.it\/prodotti\/software-e-app\/dakmaster-gestione-dati-e-reportistica\/\">DakMaster<\/a><\/td><td>Gesti\u00f3n de datos y elaboraci\u00f3n de la documentaci\u00f3n de medida<\/td><\/tr><tr><td><a href=\"https:\/\/ultrasuonindt.it\/prodotti\/misuratori-di-spessore\/dakota-pmx2-dl-precisione-universale\/\">Dakota PMX2-DL<\/a><\/td><td>Medidor de precisi\u00f3n universal con registrador de datos<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">Preguntas frecuentes<\/h2>\n\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-1757405501\"><strong class=\"schema-faq-question\">\u00bfSigue en vigor MIL-STD-45662A?<\/strong><p class=\"schema-faq-answer\">No. La revisi\u00f3n A, de 1 de agosto de 1988, consta anulada y marcada como sustituida por ISO 10012-1 y ANSI Z540-1. Existe adem\u00e1s una indicaci\u00f3n de sustituci\u00f3n del 20 de enero de 1995, que recogemos como dato de fuente \u00fanica.  <\/p><\/div><div class=\"schema-faq-section\" id=\"faq-question-1757405502\"><strong class=\"schema-faq-question\">\u00bfA qu\u00e9 referencias remitir en su lugar?<\/strong><p class=\"schema-faq-answer\">A las referencias actuales para los sistemas de calibraci\u00f3n: ANSI\/NCSL Z540-1 y la posterior Z540.3, ISO 10012 y, para la competencia de los laboratorios de ensayo y calibraci\u00f3n, ISO\/IEC 17025.<\/p><\/div><div class=\"schema-faq-section\" id=\"faq-question-1757405503\"><strong class=\"schema-faq-question\">\u00bfQu\u00e9 significa realmente \u00abtrazable NIST\u00bb?<\/strong><p class=\"schema-faq-answer\">El NIST declara que no define, especifica, garantiza ni certifica la trazabilidad metrol\u00f3gica de resultados de medida distintos de los que \u00e9l mismo proporciona, y precisa que la trazabilidad es una propiedad del resultado de una medida, no de un equipo, de un informe de calibraci\u00f3n o de un laboratorio.<\/p><\/div><\/div>\n\n<p class=\"wp-block-paragraph\">Vuelvan a <a href=\"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/\">Cualificaci\u00f3n de personal e instrumentos<\/a> o escr\u00edbannos desde la p\u00e1gina <a href=\"https:\/\/ultrasuonindt.it\/es\/contacto\/\">Contacto<\/a>.<\/p>\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">M\u00e1s informaci\u00f3n y contactos <\/h5>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Partner divisi\u00f3n sistemas e integraci\u00f3n de sensores : <a href=\"http:\/\/www.roder.it\">www.roder.it<\/a><br\/>M\u00e1s informaci\u00f3n sobre RODER SRL : <a href=\"https:\/\/ultrasuonindt.it\/chi-siamo\/\">qui\u00e9nes somos<\/a><br\/>Contacto para informaci\u00f3n general : <a href=\"mailto:info@roder.it\">info@roder.it<\/a><br\/>Contacto para informaci\u00f3n sobre estos productos : <a href=\"mailto:info@roder.it\">info@roder.it<\/a><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><br\/>La informaci\u00f3n contenida en esta p\u00e1gina web se facilita con fines meramente informativos. Aunque ha sido elaborada con el m\u00e1ximo cuidado, no constituye una oferta contractual ni un compromiso vinculante de suministro. Puede contener errores de transcripci\u00f3n, traducci\u00f3n o erratas. Para obtener informaci\u00f3n precisa y actualizada, le invitamos a ponerse en contacto directamente con nuestra empresa.    <\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Algunas im\u00e1genes presentes en este sitio web han sido generadas intencionadamente mediante Inteligencia Artificial (IA). Esto se debe a que, para muchas aplicaciones y proyectos, no es posible divulgar fotograf\u00edas de la instalaci\u00f3n o del sistema real debido a acuerdos de confidencialidad, cl\u00e1usulas de confidencialidad y acuerdos de no divulgaci\u00f3n (NDA). <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>La trazabilidad es una propiedad del resultado de medida, no un sello del equipo. Y la norma militar que muchos pliegos siguen citando est\u00e1 anulada desde hace tiempo. En los certificados de calibraci\u00f3n aparece a menudo la f\u00f3rmula \u00abtrazable NIST\u00bb, y otras tantas veces los pliegos remiten a MIL-STD-45662A. Ambas expresiones merecen una comprobaci\u00f3n, porque [&hellip;]<\/p>\n","protected":false},"author":157040980,"featured_media":3482,"parent":4691,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_yoast_wpseo_focuskw":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"La trazabilidad es una cadena documentada de calibraciones, no un sello: por qu\u00e9 MIL-STD-45662A est\u00e1 anulada y qu\u00e9 referencias rigen hoy.","_wpcom_ai_launchpad_about_page":false,"_wpcom_ai_launchpad_gallery_page":false,"_wpcom_ai_launchpad_contact_page":false,"_wpcom_ai_launchpad_events_page":false,"_wpcom_ai_launchpad_video_page":false,"_wpcom_ai_launchpad_portfolio_piece":false,"footnotes":""},"class_list":["post-3519","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Trazabilidad NIST y MIL-STD-45662A - ULTRASUONI NDT<\/title>\n<meta name=\"description\" content=\"La trazabilidad es una cadena documentada de calibraciones, no un sello: por qu\u00e9 MIL-STD-45662A est\u00e1 anulada y qu\u00e9 referencias rigen hoy.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Trazabilidad NIST y MIL-STD-45662A - ULTRASUONI NDT\" \/>\n<meta property=\"og:description\" content=\"La trazabilidad es una cadena documentada de calibraciones, no un sello: por qu\u00e9 MIL-STD-45662A est\u00e1 anulada y qu\u00e9 referencias rigen hoy.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/\" \/>\n<meta property=\"og:site_name\" content=\"ULTRASUONI NDT\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-13T02:16:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"FAQPage\"],\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/\",\"name\":\"Trazabilidad NIST y MIL-STD-45662A - ULTRASUONI NDT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1\",\"datePublished\":\"2026-09-07T15:06:32+00:00\",\"dateModified\":\"2026-09-13T02:16:00+00:00\",\"description\":\"La trazabilidad es una cadena documentada de calibraciones, no un sello: por qu\u00e9 MIL-STD-45662A est\u00e1 anulada y qu\u00e9 referencias rigen hoy.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#breadcrumb\"},\"mainEntity\":[{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405501\"},{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405502\"},{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405503\"}],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1\",\"width\":700,\"height\":700,\"caption\":\"Bloques de calibraci\u00f3n Dakota NDT\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Tecnolog\u00edas y Normas END\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Cualificaci\u00f3n de personal e instrumentos\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Trazabilidad NIST y MIL-STD-45662A\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/\",\"name\":\"ULTRASUONI NDT\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/#organization\",\"name\":\"RODER SRL\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1\",\"width\":1000,\"height\":330,\"caption\":\"RODER SRL\"},\"image\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/roder-srl\"]},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405501\",\"position\":1,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405501\",\"name\":\"\u00bfSigue en vigor MIL-STD-45662A?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. La revisi\u00f3n A, de 1 de agosto de 1988, consta anulada y marcada como sustituida por ISO 10012-1 y ANSI Z540-1. Existe adem\u00e1s una indicaci\u00f3n de sustituci\u00f3n del 20 de enero de 1995, que recogemos como dato de fuente \u00fanica.  \",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405502\",\"position\":2,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405502\",\"name\":\"\u00bfA qu\u00e9 referencias remitir en su lugar?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A las referencias actuales para los sistemas de calibraci\u00f3n: ANSI\\\/NCSL Z540-1 y la posterior Z540.3, ISO 10012 y, para la competencia de los laboratorios de ensayo y calibraci\u00f3n, ISO\\\/IEC 17025.\",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405503\",\"position\":3,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/es\\\/tecnologias-y-normas-end\\\/qualifica-di-personale-e-strumenti\\\/trazabilidad-nist-y-mil-std-45662a\\\/#faq-question-1757405503\",\"name\":\"\u00bfQu\u00e9 significa realmente \u00abtrazable NIST\u00bb?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"El NIST declara que no define, especifica, garantiza ni certifica la trazabilidad metrol\u00f3gica de resultados de medida distintos de los que \u00e9l mismo proporciona, y precisa que la trazabilidad es una propiedad del resultado de una medida, no de un equipo, de un informe de calibraci\u00f3n o de un laboratorio.\",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Trazabilidad NIST y MIL-STD-45662A - ULTRASUONI NDT","description":"La trazabilidad es una cadena documentada de calibraciones, no un sello: por qu\u00e9 MIL-STD-45662A est\u00e1 anulada y qu\u00e9 referencias rigen hoy.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/","og_locale":"es_ES","og_type":"article","og_title":"Trazabilidad NIST y MIL-STD-45662A - ULTRASUONI NDT","og_description":"La trazabilidad es una cadena documentada de calibraciones, no un sello: por qu\u00e9 MIL-STD-45662A est\u00e1 anulada y qu\u00e9 referencias rigen hoy.","og_url":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/","og_site_name":"ULTRASUONI NDT","article_modified_time":"2026-09-13T02:16:00+00:00","og_image":[{"width":700,"height":700,"url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","FAQPage"],"@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/","url":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/","name":"Trazabilidad NIST y MIL-STD-45662A - ULTRASUONI NDT","isPartOf":{"@id":"https:\/\/ultrasuonindt.it\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#primaryimage"},"image":{"@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1","datePublished":"2026-09-07T15:06:32+00:00","dateModified":"2026-09-13T02:16:00+00:00","description":"La trazabilidad es una cadena documentada de calibraciones, no un sello: por qu\u00e9 MIL-STD-45662A est\u00e1 anulada y qu\u00e9 referencias rigen hoy.","breadcrumb":{"@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#breadcrumb"},"mainEntity":[{"@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405501"},{"@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405502"},{"@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405503"}],"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#primaryimage","url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1","contentUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1","width":700,"height":700,"caption":"Bloques de calibraci\u00f3n Dakota NDT"},{"@type":"BreadcrumbList","@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/ultrasuonindt.it\/es\/"},{"@type":"ListItem","position":2,"name":"Tecnolog\u00edas y Normas END","item":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/"},{"@type":"ListItem","position":3,"name":"Cualificaci\u00f3n de personal e instrumentos","item":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/"},{"@type":"ListItem","position":4,"name":"Trazabilidad NIST y MIL-STD-45662A"}]},{"@type":"WebSite","@id":"https:\/\/ultrasuonindt.it\/es\/#website","url":"https:\/\/ultrasuonindt.it\/es\/","name":"ULTRASUONI NDT","description":"","publisher":{"@id":"https:\/\/ultrasuonindt.it\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ultrasuonindt.it\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/ultrasuonindt.it\/es\/#organization","name":"RODER SRL","url":"https:\/\/ultrasuonindt.it\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/ultrasuonindt.it\/es\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1","contentUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1","width":1000,"height":330,"caption":"RODER SRL"},"image":{"@id":"https:\/\/ultrasuonindt.it\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/roder-srl"]},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405501","position":1,"url":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405501","name":"\u00bfSigue en vigor MIL-STD-45662A?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"No. La revisi\u00f3n A, de 1 de agosto de 1988, consta anulada y marcada como sustituida por ISO 10012-1 y ANSI Z540-1. Existe adem\u00e1s una indicaci\u00f3n de sustituci\u00f3n del 20 de enero de 1995, que recogemos como dato de fuente \u00fanica.  ","inLanguage":"es"},"inLanguage":"es"},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405502","position":2,"url":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405502","name":"\u00bfA qu\u00e9 referencias remitir en su lugar?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"A las referencias actuales para los sistemas de calibraci\u00f3n: ANSI\/NCSL Z540-1 y la posterior Z540.3, ISO 10012 y, para la competencia de los laboratorios de ensayo y calibraci\u00f3n, ISO\/IEC 17025.","inLanguage":"es"},"inLanguage":"es"},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405503","position":3,"url":"https:\/\/ultrasuonindt.it\/es\/tecnologias-y-normas-end\/qualifica-di-personale-e-strumenti\/trazabilidad-nist-y-mil-std-45662a\/#faq-question-1757405503","name":"\u00bfQu\u00e9 significa realmente \u00abtrazable NIST\u00bb?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"El NIST declara que no define, especifica, garantiza ni certifica la trazabilidad metrol\u00f3gica de resultados de medida distintos de los que \u00e9l mismo proporciona, y precisa que la trazabilidad es una propiedad del resultado de una medida, no de un equipo, de un informe de calibraci\u00f3n o de un laboratorio.","inLanguage":"es"},"inLanguage":"es"}]}},"jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/PeHTL3-UL","jetpack-related-posts":[{"id":5362,"url":"https:\/\/ultrasuonindt.it\/es\/aplicaciones\/aeronautica-y-defensa\/requisitos-nadcap-y-en-4179\/","url_meta":{"origin":3519,"position":0},"title":"Requisitos NADCAP y EN 4179","author":"GSM","date":"7 de septiembre de 2026","format":false,"excerpt":"En el \u00e1mbito aeroespacial el instrumento es un eslab\u00f3n de la cadena, no su cualificaci\u00f3n. Junto a la trazabilidad metrol\u00f3gica hacen falta procedimiento escrito y personal certificado: sin ellos, el control no aguanta la auditor\u00eda. \u2713 Certificado de calibraci\u00f3n trazable NIST\u2713 Conformidad MIL-STD-45662A del sistema de calibraci\u00f3n\u2713 Calibraci\u00f3n peri\u00f3dica gestionada\u2026","rel":"","context":"Entrada similar","block_context":{"text":"Entrada similar","link":""},"img":{"alt_text":"Palpador de ultrasonidos Dakota NDT durante el procedimiento de ajuste y calibraci\u00f3n","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?fit=960%2C960&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?fit=960%2C960&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?fit=960%2C960&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?fit=960%2C960&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":2135,"url":"https:\/\/ultrasuonindt.it\/tecnologie-e-normative-ndt\/qualifica-di-personale-e-strumenti\/tracciabilita-nist-e-mil-std-45662a\/","url_meta":{"origin":3519,"position":1},"title":"Tracciabilit\u00e0 NIST e MIL-STD-45662A","author":"GSM","date":"7 de septiembre de 2026","format":false,"excerpt":"La tracciabilit\u00e0 \u00e8 una propriet\u00e0 del risultato di misura, non un marchio dello strumento. E la norma militare che molti capitolati citano ancora \u00e8 annullata da tempo. \u2713\u00a0Definizione VIM: catena documentata e ininterrotta di calibrazioni \u2713\u00a0NIST non certifica la tracciabilit\u00e0 di misure che non esegue essa stessa \u2713\u00a0MIL-STD-45662A, Rev. A\u2026","rel":"","context":"Entrada similar","block_context":{"text":"Entrada similar","link":""},"img":{"alt_text":"Blocchetti di calibrazione Dakota NDT in acciaio 4340 per taratura spessimetri ultrasonici","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":4759,"url":"https:\/\/ultrasuonindt.it\/es\/soporte\/calibrazione-e-taratura\/","url_meta":{"origin":3519,"position":2},"title":"Calibraci\u00f3n y ajuste","author":"GSM","date":"7 de septiembre de 2026","format":false,"excerpt":"La calibraci\u00f3n peri\u00f3dica no es una formalidad: es lo que hace defendible una medici\u00f3n ante un auditor o un cliente. RODER SRL la realiza en su propio laboratorio en Italia o en el fabricante, con certificado trazable NIST. \u2713 Certificado trazable NIST y conforme MIL-STD-45662A \u2713 Laboratorio RODER en Italia\u2026","rel":"","context":"Entrada similar","block_context":{"text":"Entrada similar","link":""},"img":{"alt_text":"Palpador de ultrasonidos Dakota NDT durante el procedimiento de ajuste y calibraci\u00f3n","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?fit=960%2C960&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?fit=960%2C960&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?fit=960%2C960&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_con_sonda_e_procedura_di_taratura_e_calibrazione-web-960x960-1.webp?fit=960%2C960&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":3508,"url":"https:\/\/ultrasuonindt.it\/en\/ndt-technologies-and-standards\/qualifica-di-personale-e-strumenti\/nist-traceability-and-mil-std-45662a\/","url_meta":{"origin":3519,"position":3},"title":"NIST traceability and MIL-STD-45662A","author":"GSM","date":"7 de septiembre de 2026","format":false,"excerpt":"Traceability is a property of the measurement result, not a badge on the instrument. And the military standard that many specifications still cite was cancelled long ago. \u2713 VIM definition: documented, unbroken chain of calibrations \u2713 NIST does not certify the traceability of measurements it does not itself perform \u2713\u2026","rel":"","context":"Entrada similar","block_context":{"text":"Entrada similar","link":""},"img":{"alt_text":"Dakota NDT calibration blocks in 4340 steel for adjusting ultrasonic thickness gauges","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":3511,"url":"https:\/\/ultrasuonindt.it\/fr\/technologies-et-normes-end\/qualifica-di-personale-e-strumenti\/tracabilite-nist-et-mil-std-45662a\/","url_meta":{"origin":3519,"position":4},"title":"Tra\u00e7abilit\u00e9 NIST et MIL-STD-45662A","author":"GSM","date":"7 de septiembre de 2026","format":false,"excerpt":"La tra\u00e7abilit\u00e9 est une propri\u00e9t\u00e9 du r\u00e9sultat de mesure, non un label appos\u00e9 sur l'appareil. Et la norme militaire que beaucoup de cahiers des charges citent encore est annul\u00e9e depuis longtemps. \u2713 D\u00e9finition du VIM : cha\u00eene document\u00e9e et ininterrompue d'\u00e9talonnages \u2713 Le NIST ne certifie pas la tra\u00e7abilit\u00e9 de\u2026","rel":"","context":"Entrada similar","block_context":{"text":"Entrada similar","link":""},"img":{"alt_text":"Blocs d'\u00e9talonnage Dakota NDT en acier 4340 pour le r\u00e9glage des \u00e9paisseurm\u00e8tres \u00e0 ultrasons","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":3516,"url":"https:\/\/ultrasuonindt.it\/de\/zfp-technologien-und-normen\/qualifica-di-personale-e-strumenti\/nist-rueckfuehrbarkeit-und-mil-std-45662a\/","url_meta":{"origin":3519,"position":5},"title":"NIST-R\u00fcckf\u00fchrbarkeit und MIL-STD-45662A","author":"GSM","date":"7 de septiembre de 2026","format":false,"excerpt":"R\u00fcckf\u00fchrbarkeit ist eine Eigenschaft des Messergebnisses, kein Siegel am Ger\u00e4t. Und die Milit\u00e4rnorm, die viele Leistungsverzeichnisse noch zitieren, ist l\u00e4ngst zur\u00fcckgezogen. \u2713 VIM-Definition: dokumentierte, ununterbrochene Kette von Kalibrierungen \u2713 NIST bescheinigt keine R\u00fcckf\u00fchrbarkeit von Messungen, die es nicht selbst durchf\u00fchrt \u2713 MIL-STD-45662A, Rev. A von 1988: zur\u00fcckgezogen \u2713 Aktuelle Regelwerke:\u2026","rel":"","context":"Entrada similar","block_context":{"text":"Entrada similar","link":""},"img":{"alt_text":"Dakota NDT Kalibrierbl\u00f6cke aus Stahl 4340 zur Justierung von Ultraschall-Dickenmessger\u00e4ten","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-blocchetti_di_calibrazione-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/pages\/3519","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/users\/157040980"}],"replies":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/comments?post=3519"}],"version-history":[{"count":2,"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/pages\/3519\/revisions"}],"predecessor-version":[{"id":4767,"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/pages\/3519\/revisions\/4767"}],"up":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/pages\/4691"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/media\/3482"}],"wp:attachment":[{"href":"https:\/\/ultrasuonindt.it\/es\/wp-json\/wp\/v2\/media?parent=3519"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}