{"id":116,"count":2,"description":"The <strong>ASTM E797<\/strong> standard (Standard Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method) sets out the procedures for ultrasonic thickness measurement by the manual pulse-echo contact method. It is the most widely used international reference for remaining-thickness readings on components in metal, plastic and other homogeneous materials. \n\nThis section gathers articles and practical guides on how to apply ASTM E797 correctly: choice of probe, calibration, handling of interference and interpretation of the signal.\nDakota instruments compliant with ASTM E797\n\n \t<a href=\"https:\/\/ultrasuonindt.it\/prodotti\/misuratori-di-spessore\/dakota-cx2-misuratore-di-spessore-base\/\">Dakota CX2<\/a> \u2014 basic thickness gauge for quality control, compliant with ASTM E797.\n \t<a href=\"https:\/\/ultrasuonindt.it\/prodotti\/misuratori-di-spessore\/dakota-cx6-dl-misuratore-di-spessore-con-data-logger\/\">Dakota CX6-DL<\/a> \u2014 pulse-echo with integrated data logger.\n \t<a href=\"https:\/\/ultrasuonindt.it\/prodotti\/misuratori-di-spessore\/dakota-pmx2-dl-pmx3-dl-misuratori-di-precisione-universali\/\">Dakota PMX2-DL \/ PMX3-DL<\/a> \u2014 precision gauges for thin thicknesses and high accuracy.\n\nFurther reading on the standards\n<a href=\"https:\/\/ultrasuonindt.it\/normative-ndt-misura-spessore-en-14127-astm-e797\/\">NDT standards for thickness measurement: EN 14127 and ASTM E797<\/a> \u00b7 <a href=\"https:\/\/ultrasuonindt.it\/calibrazione-1-punto-2-punti-misura-ultrasononica\/\">1-point vs 2-point calibration<\/a> \u00b7 <a href=\"https:\/\/ultrasuonindt.it\/come-funziona-misura-ultrasonica-spessore-principi-base\/\">How ultrasonic thickness measurement works<\/a>\n\nTo define an ASTM E797 procedure that fits your quality plan using Dakota instruments, contact the <a href=\"https:\/\/ultrasuonindt.it\/contatti\/\">RODER<\/a> team.","link":"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/","name":"ASTM E797 Ultrasonic Thickness Measurement","slug":"astm-e797-ultrasonic-thickness-measurement","taxonomy":"post_tag","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ASTM E797 Ultrasonic Thickness Measurement Archivi - ULTRASUONI NDT<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ASTM E797 Ultrasonic Thickness Measurement Archivi - ULTRASUONI NDT\" \/>\n<meta property=\"og:description\" content=\"The ASTM E797 standard (Standard Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method) sets out the procedures for ultrasonic thickness measurement by the manual pulse-echo contact method. It is the most widely used international reference for remaining-thickness readings on components in metal, plastic and other homogeneous materials. This section gathers articles and practical guides on how to apply ASTM E797 correctly: choice of probe, calibration, handling of interference and interpretation of the signal. Dakota instruments compliant with ASTM E797  Dakota CX2 \u2014 basic thickness gauge for quality control, compliant with ASTM E797.  Dakota CX6-DL \u2014 pulse-echo with integrated data logger.  Dakota PMX2-DL \/ PMX3-DL \u2014 precision gauges for thin thicknesses and high accuracy. Further reading on the standards NDT standards for thickness measurement: EN 14127 and ASTM E797 \u00b7 1-point vs 2-point calibration \u00b7 How ultrasonic thickness measurement works To define an ASTM E797 procedure that fits your quality plan using Dakota instruments, contact the RODER team.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/\" \/>\n<meta property=\"og:site_name\" content=\"ULTRASUONI NDT\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"CollectionPage\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/argomento\\\/astm-e797-ultrasonic-thickness-measurement\\\/\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/argomento\\\/astm-e797-ultrasonic-thickness-measurement\\\/\",\"name\":\"ASTM E797 Ultrasonic Thickness Measurement Archivi - ULTRASUONI NDT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/argomento\\\/astm-e797-ultrasonic-thickness-measurement\\\/#breadcrumb\"},\"inLanguage\":\"en-US\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/argomento\\\/astm-e797-ultrasonic-thickness-measurement\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ASTM E797 Ultrasonic Thickness Measurement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\",\"name\":\"ULTRASUONI NDT\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#organization\",\"name\":\"RODER SRL\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1\",\"width\":1000,\"height\":330,\"caption\":\"RODER SRL\"},\"image\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/roder-srl\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ASTM E797 Ultrasonic Thickness Measurement Archivi - ULTRASUONI NDT","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/","og_locale":"en_US","og_type":"article","og_title":"ASTM E797 Ultrasonic Thickness Measurement Archivi - ULTRASUONI NDT","og_description":"The ASTM E797 standard (Standard Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method) sets out the procedures for ultrasonic thickness measurement by the manual pulse-echo contact method. It is the most widely used international reference for remaining-thickness readings on components in metal, plastic and other homogeneous materials. This section gathers articles and practical guides on how to apply ASTM E797 correctly: choice of probe, calibration, handling of interference and interpretation of the signal. Dakota instruments compliant with ASTM E797  Dakota CX2 \u2014 basic thickness gauge for quality control, compliant with ASTM E797.  Dakota CX6-DL \u2014 pulse-echo with integrated data logger.  Dakota PMX2-DL \/ PMX3-DL \u2014 precision gauges for thin thicknesses and high accuracy. Further reading on the standards NDT standards for thickness measurement: EN 14127 and ASTM E797 \u00b7 1-point vs 2-point calibration \u00b7 How ultrasonic thickness measurement works To define an ASTM E797 procedure that fits your quality plan using Dakota instruments, contact the RODER team.","og_url":"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/","og_site_name":"ULTRASUONI NDT","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"CollectionPage","@id":"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/","url":"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/","name":"ASTM E797 Ultrasonic Thickness Measurement Archivi - ULTRASUONI NDT","isPartOf":{"@id":"https:\/\/ultrasuonindt.it\/en\/#website"},"breadcrumb":{"@id":"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/#breadcrumb"},"inLanguage":"en-US"},{"@type":"BreadcrumbList","@id":"https:\/\/ultrasuonindt.it\/en\/argomento\/astm-e797-ultrasonic-thickness-measurement\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ultrasuonindt.it\/en\/"},{"@type":"ListItem","position":2,"name":"ASTM E797 Ultrasonic Thickness Measurement"}]},{"@type":"WebSite","@id":"https:\/\/ultrasuonindt.it\/en\/#website","url":"https:\/\/ultrasuonindt.it\/en\/","name":"ULTRASUONI NDT","description":"","publisher":{"@id":"https:\/\/ultrasuonindt.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ultrasuonindt.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ultrasuonindt.it\/en\/#organization","name":"RODER SRL","url":"https:\/\/ultrasuonindt.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ultrasuonindt.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1","contentUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1","width":1000,"height":330,"caption":"RODER SRL"},"image":{"@id":"https:\/\/ultrasuonindt.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/roder-srl"]}]}},"_links":{"self":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/tags\/116","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/tags"}],"about":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/taxonomies\/post_tag"}],"wp:post_type":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/posts?tags=116"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}