{"id":6356,"date":"2026-05-06T10:07:53","date_gmt":"2026-05-06T10:07:53","guid":{"rendered":"https:\/\/ultrasuonindt.it\/products\/probes-and-accessories\/ultrasonic-couplants\/"},"modified":"2026-10-03T20:16:35","modified_gmt":"2026-10-03T20:16:35","slug":"ultrasonic-couplants","status":"publish","type":"page","link":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/","title":{"rendered":"Ultrasonic Couplants"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-61d584a3 wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-ba02fbf7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<figure class=\"wp-block-image size-full has-custom-border coblocks-animate\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"700\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?resize=700%2C700&#038;ssl=1\" alt=\"\" class=\"wp-image-1585\" style=\"border-width:1px;border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-left-radius:20px;border-bottom-right-radius:20px\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?w=700&amp;ssl=1 700w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?resize=150%2C150&amp;ssl=1 150w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<p class=\"has-text-color has-background wp-block-paragraph\" style=\"border-radius:0px 6px 6px 0px;border-left-color:#2980B9;border-left-style:solid;border-left-width:5px;color:#1A5276;background-color:#EBF5FB;padding-top:14px;padding-right:16px;padding-bottom:14px;padding-left:16px;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.612), 20px);font-style:italic\">The couplant is the physical bridge between the ultrasonic probe and the material: without couplant there is no measurement. RODER SRL supplies two gels and two high-temperature pastes, for use from -30 to +520 \u00b0C. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list is-style-checkbox\">\n<li><strong>Types:<\/strong> gels and high-temperature pastes<\/li>\n\n\n\n<li><strong>Gels:<\/strong> GEL-ACC-STD 0 \/ 80 \u00b0C, GEL-ACC-EXT -20 \/ 120 \u00b0C<\/li>\n\n\n\n<li><strong>Pastes:<\/strong> PST-ACC-MHT -30 \/ +300 \u00b0C, PST-ACC-UHT +100 \/ 520 \u00b0C<\/li>\n\n\n\n<li><strong>Pack sizes:<\/strong> 500 ml (gels), 170 g and 200 g (pastes)<\/li>\n\n\n\n<li><strong>Compliance:<\/strong> RCCM<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Without a good couplant, ultrasonic measurement is impossible: the air between the probe and the material reflects almost all of the signal and prevents the ultrasonic wave from entering the part. The couplant fills this physical gap, reducing the acoustic impedance mismatch at the interface and allowing optimal signal transfer. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RODER SRL supplies four ultrasonic couplants: two gels and two special high-temperature pastes. Our technical team is at your disposal to help choose the product according to the operating temperature. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The gels cover temperatures from -20 to 120 \u00b0C. For hot surfaces, the special pastes PST-ACC-MHT (from -30 to +300 \u00b0C) and PST-ACC-UHT (from +100 to 520 \u00b0C) are available, to be used with high-temperature probes. <\/p>\n<\/div>\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-cover is-light popmake-4066 popmake-739\" style=\"border-width:1px;min-height:250px;aspect-ratio:unset;\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"250\" class=\"wp-block-cover__image-background wp-image-727 size-full\" alt=\"\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=1200%2C250&#038;ssl=1\" data-object-fit=\"cover\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?w=1200&amp;ssl=1 1200w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=300%2C63&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=1024%2C213&amp;ssl=1 1024w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=768%2C160&amp;ssl=1 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-30 has-background-dim\" style=\"background-color:#d3d6dc\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-15701bb7 wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-right has-ti-fg-color is-style-default has-luminous-vivid-amber-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"font-size:clamp(21.536px, 1.346rem + ((1vw - 3.2px) * 1.374), 35px);\"><strong>Need help choosing the right product?<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-b507c051 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-4066 popmake-739\"><a class=\"wp-block-button__link has-ti-accent-color has-cyan-bluish-gray-background-color has-text-color has-background has-link-color wp-element-button\">Contact us<\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\">Why a couplant is needed<\/h2>\n\n<p class=\"wp-block-paragraph\">Ultrasound travels well in solids and in liquids, but <strong>almost not at all in air<\/strong>. The difference in acoustic impedance between air and metal is so great that 99.99% of the ultrasonic signal generated by the probe is <strong>reflected at the air-surface interface<\/strong> without penetrating the part. For this reason even the slightest surface irregularity or a microscopic layer of air can spoil the measurement.  <\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Couplant<\/strong> solves the problem: it fills the micro-irregularities between probe and surface with a medium of intermediate acoustic impedance, ensuring that the <strong>ultrasonic beam enters the material without losses<\/strong>. Choosing the right couplant directly affects the sensitivity, repeatability and accuracy of the measurement. <\/p>\n\n<h2 class=\"wp-block-heading\">The four couplants available<\/h2>\n\n<p class=\"wp-block-paragraph\">The range comprises four products, differing in temperature range and pack size:<\/p>\n\n<div class=\"wp-block-media-text is-stacked-on-mobile is-vertically-aligned-center\" style=\"grid-template-columns:35% auto\"><figure class=\"wp-block-media-text__media\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-gel_acc_std-web-400x400-1.webp?resize=400%2C400&#038;ssl=1\" alt=\"GEL-ACC-STD ultrasonic couplant gel, 500 ml pack\" class=\"wp-image-8939 size-full\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-gel_acc_std-web-400x400-1.webp?w=400&amp;ssl=1 400w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-gel_acc_std-web-400x400-1.webp?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-gel_acc_std-web-400x400-1.webp?resize=150%2C150&amp;ssl=1 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\">GEL-ACC-STD<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Yellow rust-inhibiting couplant gel, RCCM compliant. Standard temperature range 0 \/ 80 \u00b0C. 500 ml pack.  <\/p>\n<\/div><\/div>\n\n<div class=\"wp-block-media-text is-stacked-on-mobile is-vertically-aligned-center\" style=\"grid-template-columns:35% auto\"><figure class=\"wp-block-media-text__media\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-gel_acc_ext-web-400x400-1.webp?resize=400%2C400&#038;ssl=1\" alt=\"GEL-ACC-EXT ultrasonic couplant gel, 500 ml pack\" class=\"wp-image-8940 size-full\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-gel_acc_ext-web-400x400-1.webp?w=400&amp;ssl=1 400w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-gel_acc_ext-web-400x400-1.webp?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-gel_acc_ext-web-400x400-1.webp?resize=150%2C150&amp;ssl=1 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\">GEL-ACC-EXT<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Blue corrosion-inhibiting couplant gel, RCCM compliant. Extended temperature range -20 \/ 120 \u00b0C. 500 ml pack.  <\/p>\n<\/div><\/div>\n\n<div class=\"wp-block-media-text is-stacked-on-mobile is-vertically-aligned-center\" style=\"grid-template-columns:35% auto\"><figure class=\"wp-block-media-text__media\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-pst_acc_mht-web-400x400-1.webp?resize=400%2C400&#038;ssl=1\" alt=\"PST-ACC-MHT ultrasonic couplant paste, 170 g pack\" class=\"wp-image-8941 size-full\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-pst_acc_mht-web-400x400-1.webp?w=400&amp;ssl=1 400w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-pst_acc_mht-web-400x400-1.webp?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-pst_acc_mht-web-400x400-1.webp?resize=150%2C150&amp;ssl=1 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\">PST-ACC-MHT<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Special paste for ultrasonic coupling at medium temperature, -30 \/ +300 \u00b0C. Non-flammable and produces no fumes. RCCM compliant. 170 g pack.   <\/p>\n<\/div><\/div>\n\n<div class=\"wp-block-media-text is-stacked-on-mobile is-vertically-aligned-center\" style=\"grid-template-columns:35% auto\"><figure class=\"wp-block-media-text__media\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-pst_acc_uht-web-400x400-1.webp?resize=400%2C400&#038;ssl=1\" alt=\"PST-ACC-UHT ultrasonic couplant paste, 200 g pack\" class=\"wp-image-8942 size-full\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-pst_acc_uht-web-400x400-1.webp?w=400&amp;ssl=1 400w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-pst_acc_uht-web-400x400-1.webp?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/accoppiante_ultrasuoni-pst_acc_uht-web-400x400-1.webp?resize=150%2C150&amp;ssl=1 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\">PST-ACC-UHT<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Special paste for ultrasonic coupling at very high temperature, +100 \/ 520 \u00b0C. Non-flammable and produces no fumes. RCCM compliant. 200 g pack.   <\/p>\n<\/div><\/div>\n\n<h2 class=\"wp-block-heading\">How to choose the right couplant<\/h2>\n\n<ul class=\"wp-block-list\">\n<li><strong>From 0 to 80 \u00b0C<\/strong>: GEL-ACC-STD gel<\/li>\n\n\n\n<li><strong>From -20 to 120 \u00b0C<\/strong>: GEL-ACC-EXT gel<\/li>\n\n\n\n<li><strong>From -30 to +300 \u00b0C<\/strong>: PST-ACC-MHT paste<\/li>\n\n\n\n<li><strong>From +100 to 520 \u00b0C<\/strong>: PST-ACC-UHT paste<\/li>\n\n\n\n<li><strong>Hot surfaces<\/strong>: pair the couplant with a high-temperature probe<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Good practice in application<\/h2>\n\n<ul class=\"wp-block-list\">\n<li><strong>Surface cleaning<\/strong>: remove oxides, dust and residues before applying the couplant<\/li>\n\n\n\n<li><strong>Quantity<\/strong>: a generous drop is enough; avoid waste<\/li>\n\n\n\n<li><strong>Repeatability<\/strong>: use the same quantity and the same settling time for comparative measurements<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n<ul class=\"wp-block-list\">\n<li><strong>Every thickness measurement<\/strong> with dual element corrosion probes<\/li>\n\n\n\n<li><strong>Precision measurements<\/strong> with single element probes<\/li>\n\n\n\n<li><strong>Flaw inspection<\/strong> with shear wave probes and wedges<\/li>\n\n\n\n<li><strong>Bolt tension<\/strong> under the bolt head<\/li>\n\n\n\n<li><strong>HT measurements<\/strong> on steam plant, heat exchangers and furnaces with high-temperature couplant<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Frequently asked questions<\/h2>\n\n<h3 class=\"wp-block-heading\">Can I use oil or grease instead of couplant?<\/h3>\n\n<p class=\"wp-block-paragraph\">Technically possible for occasional measurements, but not recommended: oil and greases have a different acoustic impedance from an optimised couplant and can give less accurate readings. In addition, some greases contain additives that attack the seal of precision probes. Always use a couplant formulated for ultrasonics.  <\/p>\n\n<h3 class=\"wp-block-heading\">How long does a pack of couplant last?<\/h3>\n\n<p class=\"wp-block-paragraph\">How long it lasts depends on the intensity of use and the amount applied per measurement. A standard pack is typically enough for hundreds of measurements if used sparingly (one generous drop is enough). Always check the expiry date shown on the pack.  <\/p>\n\n<h3 class=\"wp-block-heading\">Are the high-temperature pastes also suitable at room temperature?<\/h3>\n\n<p class=\"wp-block-paragraph\">It depends on the product. PST-ACC-MHT is rated from -30 to +300 \u00b0C; PST-ACC-UHT is rated from +100 to 520 \u00b0C and is therefore not suitable at room temperature. For measurements at room temperature, the GEL-ACC-STD and GEL-ACC-EXT gels are used.  <\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>Request availability and a quotation:<\/strong> <a href=\"https:\/\/ultrasuonindt.it\/en\/contact\/\">contact us<\/a> stating the type of application and the quantity required.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ultrasonic couplants: GEL-ACC-STD (0 \/ 80 \u00b0C) and GEL-ACC-EXT (-20 \/ 120 \u00b0C) gels, PST-ACC-MHT (-30 \/ +300 \u00b0C) and PST-ACC-UHT (+100 \/ 520 \u00b0C) high-temperature pastes. RCCM compliant. <\/p>\n","protected":false},"author":157040980,"featured_media":2750,"parent":3008,"menu_order":7,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_yoast_wpseo_focuskw":"ultrasonic couplants","_yoast_wpseo_title":"Ultrasonic couplants: gels and pastes | ULTRASUONI NDT","_yoast_wpseo_metadesc":"Ultrasonic couplants: GEL-ACC-STD (0\/80 \u00b0C) and GEL-ACC-EXT (-20\/120 \u00b0C) gels, PST-ACC-MHT (up to +300 \u00b0C) and PST-ACC-UHT (up to 520 \u00b0C) pastes. RCCM compliant.","jetpack_seo_llms_txt_always_include":false,"_wpcom_ai_launchpad_about_page":false,"_wpcom_ai_launchpad_gallery_page":false,"_wpcom_ai_launchpad_contact_page":false,"_wpcom_ai_launchpad_events_page":false,"_wpcom_ai_launchpad_video_page":false,"_wpcom_ai_launchpad_portfolio_piece":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"footnotes":""},"class_list":["post-6356","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ultrasonic couplants: gels and pastes | ULTRASUONI NDT<\/title>\n<meta name=\"description\" content=\"Ultrasonic couplants: GEL-ACC-STD (0\/80 \u00b0C) and GEL-ACC-EXT (-20\/120 \u00b0C) gels, PST-ACC-MHT (up to +300 \u00b0C) and PST-ACC-UHT (up to 520 \u00b0C) pastes. RCCM compliant.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ultrasonic couplants: gels and pastes | ULTRASUONI NDT\" \/>\n<meta property=\"og:description\" content=\"Ultrasonic couplants: GEL-ACC-STD (0\/80 \u00b0C) and GEL-ACC-EXT (-20\/120 \u00b0C) gels, PST-ACC-MHT (up to +300 \u00b0C) and PST-ACC-UHT (up to 520 \u00b0C) pastes. RCCM compliant.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/\" \/>\n<meta property=\"og:site_name\" content=\"ULTRASUONI NDT\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-03T20:16:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/ultrasonic-couplants\\\/\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/ultrasonic-couplants\\\/\",\"name\":\"Ultrasonic couplants: gels and pastes | ULTRASUONI NDT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/ultrasonic-couplants\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/ultrasonic-couplants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1\",\"datePublished\":\"2026-05-06T10:07:53+00:00\",\"dateModified\":\"2026-10-03T20:16:35+00:00\",\"description\":\"Ultrasonic couplants: GEL-ACC-STD (0\\\/80 \u00b0C) and GEL-ACC-EXT (-20\\\/120 \u00b0C) gels, PST-ACC-MHT (up to +300 \u00b0C) and PST-ACC-UHT (up to 520 \u00b0C) pastes. RCCM compliant.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/ultrasonic-couplants\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/ultrasonic-couplants\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/ultrasonic-couplants\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1\",\"width\":700,\"height\":700,\"caption\":\"Dakota NDT ultrasonic couplants\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/ultrasonic-couplants\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Probes and Accessories\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/probes-and-accessories\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Ultrasonic Couplants\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\",\"name\":\"ULTRASUONI NDT\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#organization\",\"name\":\"RODER SRL\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1\",\"width\":1000,\"height\":330,\"caption\":\"RODER SRL\"},\"image\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/roder-srl\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ultrasonic couplants: gels and pastes | ULTRASUONI NDT","description":"Ultrasonic couplants: GEL-ACC-STD (0\/80 \u00b0C) and GEL-ACC-EXT (-20\/120 \u00b0C) gels, PST-ACC-MHT (up to +300 \u00b0C) and PST-ACC-UHT (up to 520 \u00b0C) pastes. RCCM compliant.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/","og_locale":"en_US","og_type":"article","og_title":"Ultrasonic couplants: gels and pastes | ULTRASUONI NDT","og_description":"Ultrasonic couplants: GEL-ACC-STD (0\/80 \u00b0C) and GEL-ACC-EXT (-20\/120 \u00b0C) gels, PST-ACC-MHT (up to +300 \u00b0C) and PST-ACC-UHT (up to 520 \u00b0C) pastes. RCCM compliant.","og_url":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/","og_site_name":"ULTRASUONI NDT","article_modified_time":"2026-10-03T20:16:35+00:00","og_image":[{"width":700,"height":700,"url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/","url":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/","name":"Ultrasonic couplants: gels and pastes | ULTRASUONI NDT","isPartOf":{"@id":"https:\/\/ultrasuonindt.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/#primaryimage"},"image":{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1","datePublished":"2026-05-06T10:07:53+00:00","dateModified":"2026-10-03T20:16:35+00:00","description":"Ultrasonic couplants: GEL-ACC-STD (0\/80 \u00b0C) and GEL-ACC-EXT (-20\/120 \u00b0C) gels, PST-ACC-MHT (up to +300 \u00b0C) and PST-ACC-UHT (up to 520 \u00b0C) pastes. RCCM compliant.","breadcrumb":{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/#primaryimage","url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1","contentUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1","width":700,"height":700,"caption":"Dakota NDT ultrasonic couplants"},{"@type":"BreadcrumbList","@id":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/ultrasonic-couplants\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ultrasuonindt.it\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/ultrasuonindt.it\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Probes and Accessories","item":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/"},{"@type":"ListItem","position":4,"name":"Ultrasonic Couplants"}]},{"@type":"WebSite","@id":"https:\/\/ultrasuonindt.it\/en\/#website","url":"https:\/\/ultrasuonindt.it\/en\/","name":"ULTRASUONI NDT","description":"","publisher":{"@id":"https:\/\/ultrasuonindt.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ultrasuonindt.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ultrasuonindt.it\/en\/#organization","name":"RODER SRL","url":"https:\/\/ultrasuonindt.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ultrasuonindt.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1","contentUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1","width":1000,"height":330,"caption":"RODER SRL"},"image":{"@id":"https:\/\/ultrasuonindt.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/roder-srl"]}]}},"jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/PeHTL3-1Ew","jetpack-related-posts":[{"id":6375,"url":"https:\/\/ultrasuonindt.it\/fr\/produits\/sondes-et-accessoires\/couplants-ultrasonores\/","url_meta":{"origin":6356,"position":0},"title":"Couplants ultrasonores","author":"GSM","date":"6 May 2026","format":false,"excerpt":"Couplants pour ultrasons : gels GEL-ACC-STD (0 \/ 80 \u00b0C) et GEL-ACC-EXT (-20 \/ 120 \u00b0C), p\u00e2tes haute temp\u00e9rature PST-ACC-MHT (-30 \/ +300 \u00b0C) et PST-ACC-UHT (+100 \/ 520 \u00b0C). Conformes RCCM.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Couplants \u00e0 ultrasons Dakota NDT en formulation standard et haute temp\u00e9rature","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":1561,"url":"https:\/\/ultrasuonindt.it\/prodotti\/sonde-e-accessori\/liquidi-accoppianti-ultrasonici\/","url_meta":{"origin":6356,"position":1},"title":"Liquidi Accoppianti Ultrasonici","author":"GSM","date":"6 May 2026","format":false,"excerpt":"Liquidi accoppianti per ultrasuoni: gel GEL-ACC-STD (0 \/ 80 \u00b0C) e GEL-ACC-EXT (-20 \/ 120 \u00b0C), paste per alta temperatura PST-ACC-MHT (-30 \/ +300 \u00b0C) e PST-ACC-UHT (+100 \/ 520 \u00b0C). Conformi RCCM.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Liquidi accoppianti ultrasonici Dakota NDT in formulazione standard e alta temperatura","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":6424,"url":"https:\/\/ultrasuonindt.it\/es\/productos\/sondas-y-accesorios\/acoplantes-ultrasonicos\/","url_meta":{"origin":6356,"position":2},"title":"Acoplantes ultras\u00f3nicos","author":"GSM","date":"6 May 2026","format":false,"excerpt":"Acoplantes para ultrasonidos: geles GEL-ACC-STD (0 \/ 80 \u00b0C) y GEL-ACC-EXT (-20 \/ 120 \u00b0C), pastas para alta temperatura PST-ACC-MHT (-30 \/ +300 \u00b0C) y PST-ACC-UHT (+100 \/ 520 \u00b0C). Conformes a RCCM.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Acoplantes ultras\u00f3nicos Dakota NDT en formulaci\u00f3n est\u00e1ndar y de alta temperatura","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":6404,"url":"https:\/\/ultrasuonindt.it\/de\/produkte\/pruefkoepfe-und-zubehoer\/ultraschall-koppelmittel\/","url_meta":{"origin":6356,"position":3},"title":"Ultraschall-Koppelmittel","author":"GSM","date":"6 May 2026","format":false,"excerpt":"Ultraschall-Koppelmittel: Gele GEL-ACC-STD (0 \/ 80 \u00b0C) und GEL-ACC-EXT (-20 \/ 120 \u00b0C), Hochtemperaturpasten PST-ACC-MHT (-30 \/ +300 \u00b0C) und PST-ACC-UHT (+100 \/ 520 \u00b0C). RCCM-konform.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Dakota NDT Ultraschall-Koppelmittel in der Standard- und der Hochtemperaturrezeptur","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-liquidi_accoppianti_per_strumenti_ad_ultrasuoni-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":3718,"url":"https:\/\/ultrasuonindt.it\/en\/products\/thickness-gauges\/dakota-cx2-basic-thickness-gauge\/","url_meta":{"origin":6356,"position":4},"title":"Dakota CX2 \u2013 Basic Thickness Gauge","author":"GSM","date":"8 June 2026","format":false,"excerpt":"The Dakota CX2 is the entry-level ultrasonic thickness gauge of the Dakota NDT range: Pulse-Echo mode, range 0.63-500 mm, accuracy \u00b10.1 mm, 39 preset materials, 2.4\" colour TFT display, compliant with ASTM E797, EN 14127 and EN 15317. Ideal for quality control, goods-in inspection and inspections on uncoated surfaces.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Dakota NDT CX2 entry-level ultrasonic thickness gauge","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-strumento_cx2_per_misure_ad_ultrasuoni_di_spessore-web-680x680-1.webp?fit=680%2C680&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-strumento_cx2_per_misure_ad_ultrasuoni_di_spessore-web-680x680-1.webp?fit=680%2C680&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-strumento_cx2_per_misure_ad_ultrasuoni_di_spessore-web-680x680-1.webp?fit=680%2C680&ssl=1&resize=525%2C300 1.5x"},"classes":[]},{"id":3008,"url":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/","url_meta":{"origin":6356,"position":5},"title":"Probes and Accessories","author":"GSM","date":"16 April 2026","format":false,"excerpt":"Quick selection guide What you need to doCatalogue itemThickness measurement on corrosion-affected surfacesTransducers for corrosion thickness gaugesPrecision thickness measurementTransducers for precision thickness gaugesFlaw detectionTransducers for flaw detectorsBolt tension measurementTransducers for bolt tension monitorsConnecting the probe to the instrumentTransducer cablesInstrument calibration and verificationCalibration blocksPrecision measurements with delay lineDelay line tipsAcoustic coupling\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"High-frequency ultrasonic probes with delay line for Dakota NDT thickness gauges","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_di_sonde_alta_frequenza_con_delay_line_ad_ultrasuoni-web-387x387-1.webp?fit=387%2C387&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]}],"_links":{"self":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages\/6356","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/users\/157040980"}],"replies":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/comments?post=6356"}],"version-history":[{"count":7,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages\/6356\/revisions"}],"predecessor-version":[{"id":9529,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages\/6356\/revisions\/9529"}],"up":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages\/3008"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/media\/2750"}],"wp:attachment":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/media?parent=6356"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}