{"id":2187,"date":"2026-06-08T15:21:04","date_gmt":"2026-06-08T15:21:04","guid":{"rendered":"https:\/\/ultrasuonindt.it\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/"},"modified":"2026-10-20T20:10:01","modified_gmt":"2026-10-20T20:10:01","slug":"dakota-fx70-dl-portable-ultrasonic-flaw-detector","status":"publish","type":"page","link":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/","title":{"rendered":"Dakota FX70-DL \u2013 Portable Ultrasonic Flaw Detector"},"content":{"rendered":"\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-61d584a3 wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-ba02fbf7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<figure class=\"wp-block-image size-full has-custom-border coblocks-animate\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"387\" height=\"387\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?resize=387%2C387&#038;ssl=1\" alt=\"Dakota NDT FX70 Flaw Detector hero image for ultrasonic flaw and crack measurement\" class=\"wp-image-987\" style=\"border-width:1px;border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-left-radius:20px;border-bottom-right-radius:20px\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?w=387&amp;ssl=1 387w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?resize=150%2C150&amp;ssl=1 150w\" sizes=\"auto, (max-width: 387px) 100vw, 387px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<p class=\"has-text-color has-background wp-block-paragraph\" style=\"border-radius:0px 6px 6px 0px;border-left-color:#2980B9;border-left-style:solid;border-left-width:5px;color:#1A5276;background-color:#EBF5FB;padding-top:14px;padding-right:16px;padding-bottom:14px;padding-left:16px;font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.612), 20px);font-style:italic\">The <strong>Dakota FX70-DL<\/strong> and <strong>FX71-DL<\/strong> are <strong>portable<\/strong> ultrasonic <strong>flaw detectors<\/strong> with <strong>A-Scan<\/strong>, <strong>B-Scan<\/strong> and <strong>dual mode<\/strong> flaw + thickness. A complete solution for <strong>field inspections<\/strong>. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list is-style-checkbox\">\n<li><strong>Portable :<\/strong> For field inspections<\/li>\n\n\n\n<li><strong>Dual mode :<\/strong> Flaws and thickness<\/li>\n\n\n\n<li><strong>A-Scan B-Scan :<\/strong> Display and mapping<\/li>\n\n\n\n<li><strong>DAC TCG :<\/strong> Automatic compensation curves<\/li>\n\n\n\n<li><strong>Built-in datalogger :<\/strong> Extended memory in the field<\/li>\n\n\n\n<li><strong>Pulse-Echo Pitch-Catch :<\/strong> Standard NDT techniques<\/li>\n\n\n\n<li><strong>P\/N Z-221-0005 :<\/strong> Official Dakota part number<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Dakota FX70-DL<\/strong> and <strong>FX71-DL<\/strong> are <strong>ultrasonic flaw detectors<\/strong> in a <strong>portable<\/strong> format, designed for <strong>field inspections<\/strong> of welds, castings and mechanical components. They combine <strong>flaw detection<\/strong> and <strong>thickness measurement<\/strong> in a single rugged instrument, with <strong>full traceability<\/strong> and a <strong>backlit display<\/strong>, Versatile instruments covering both flaw detection and thickness measurement. <\/p>\n\n\n\n<div id=\"indice\" class=\"wp-block-group ndt-indice ndt-indice-card is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\">On this page<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#posizionamento\">Positioning within the Dakota range<\/a><\/li>\n\n\n\n<li><a href=\"#duplice-funzionalita\">Dual functionality: flaw detector + thickness gauge<\/a><\/li>\n\n\n\n<li><a href=\"#quando-scegliere\">When to choose the Dakota FX70-DL<\/a><\/li>\n\n\n\n<li><a href=\"#modalita-misura\">Flaw detection modes<\/a><\/li>\n\n\n\n<li><a href=\"#caratteristiche\">Main features<\/a><\/li>\n\n\n\n<li><a href=\"#specifiche\">Technical specifications<\/a><\/li>\n\n\n\n<li><a href=\"#applicazioni\">Typical applications<\/a><\/li>\n\n\n\n<li><a href=\"#fornitura\">Scope of supply<\/a><\/li>\n\n\n\n<li class=\"ndt-indice-evidenza\"><a href=\"#codici-ordine\">Order codes: instrument, probes and accessories<\/a><\/li>\n\n\n\n<li><a href=\"#download\">Documentation download<\/a><\/li>\n\n\n\n<li><a href=\"#normative\">Standards and certifications<\/a><\/li>\n\n\n\n<li><a href=\"#faq\">Frequently asked questions<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Distinctive features include <strong>A-Scan display<\/strong> and <strong>B-Scan<\/strong>, <strong>DAC and TCG curves<\/strong> for <strong>flaw evaluation<\/strong>, <strong>Pulse-Echo<\/strong> and <strong>Pitch-Catch<\/strong> techniques, a <strong>datalogger<\/strong> for documented inspections and a <strong>USB output<\/strong>. Compatible with the <strong>Dakota transducer range<\/strong>, single and angle-beam, for NDT applications on steel and metal alloys, Dedicated software allows structured archiving of inspections and the generation of technical reports. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Portable Ultrasonic Flaw Detector<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Suitable for <strong>weld inspection<\/strong> to industry standards (including <strong>AWS D1<\/strong>), <strong>inspections on aerospace components<\/strong>, <strong>pipelines<\/strong> and <strong>metal structures<\/strong>. Available from <strong>RODER SRL<\/strong>, official <strong>Dakota NDT<\/strong> distributor, with dedicated <strong>calibration, repair<\/strong> and <strong>technical support<\/strong>. P\/N <strong>Z-221-0005<\/strong>. Also recommended for mobile inspection services operating across several industrial sites.  <\/p>\n<\/div>\n\n<p class=\"wp-block-paragraph\">The <strong>Dakota FX70-DL<\/strong> (currently marketed as the <strong>FX71-DL<\/strong>, P\/N <strong>Z-221-0005<\/strong>, technical designation DFX-7+) is the <strong>portable ultrasonic flaw detector<\/strong> in the Dakota NDT range. A <strong>two-in-one<\/strong> instrument combining advanced flaw detection functions (with Zero Crossing, Flank, Peak, <strong>TRIG<\/strong>, <strong>DAC<\/strong>, <strong>TCG<\/strong> detection modes) and thickness measurement with simultaneous coating and material capability. <strong>4 GB<\/strong> memory with A-Scans and B-Scans stored in alphanumeric batches, full data logger, USB transfer to PC via DakMaster\u2122. The instrument is <strong>EN 12668-1 compliant<\/strong>, the European reference standard for ultrasonic flaw detection equipment.   <\/p>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1720\" height=\"1200\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-FX71-DL_rilevatore_di_difetti_ad_ultrasuoni.jpeg?resize=1720%2C1200&#038;ssl=1\" alt=\"Dakota FX70-DL \/ FX71-DL portable ultrasonic flaw detector with A-Scan and B-Scan\" class=\"wp-image-265\" style=\"width:600px;height:auto\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-FX71-DL_rilevatore_di_difetti_ad_ultrasuoni.jpeg?w=1720&amp;ssl=1 1720w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-FX71-DL_rilevatore_di_difetti_ad_ultrasuoni.jpeg?resize=300%2C209&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-FX71-DL_rilevatore_di_difetti_ad_ultrasuoni.jpeg?resize=1024%2C714&amp;ssl=1 1024w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-FX71-DL_rilevatore_di_difetti_ad_ultrasuoni.jpeg?resize=768%2C536&amp;ssl=1 768w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-FX71-DL_rilevatore_di_difetti_ad_ultrasuoni.jpeg?resize=1536%2C1072&amp;ssl=1 1536w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-cover is-light popmake-4066 popmake-739\" style=\"border-width:1px;min-height:250px;aspect-ratio:unset;\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"250\" class=\"wp-block-cover__image-background wp-image-727 size-full\" alt=\"\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=1200%2C250&#038;ssl=1\" data-object-fit=\"cover\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?w=1200&amp;ssl=1 1200w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=300%2C63&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=1024%2C213&amp;ssl=1 1024w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/banner_technical_support_choose_products.png?resize=768%2C160&amp;ssl=1 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-30 has-background-dim\" style=\"background-color:#d3d6dc\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-15701bb7 wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-right has-ti-fg-color is-style-default has-luminous-vivid-amber-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"font-size:clamp(21.536px, 1.346rem + ((1vw - 3.2px) * 1.374), 35px);\"><strong>Need help choosing the right product?<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-b507c051 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-4066 popmake-739\"><a class=\"wp-block-button__link has-ti-accent-color has-cyan-bluish-gray-background-color has-text-color has-background has-link-color wp-element-button\">Contact us<\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 id=\"posizionamento\" class=\"wp-block-heading\">Positioning within the Dakota range<\/h2>\n\n<p class=\"wp-block-paragraph\">The Dakota FX70-DL is the entry instrument in the <strong>Flaw Detector<\/strong> category of the Dakota NDT range. It shares its technology base with the <a href=\"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx81-dl-benchtop-flaw-detector\/\">FX81-DL benchtop<\/a> model (both are developments of the DFX platform), but is characterised by its <strong>portable form factor<\/strong> \u2014 397 g, dimensions 63.5 \u00d7 165 \u00d7 31.5 mm, powered by 3 AA batteries \u2014 ideal for field inspections, welds in awkward positions, access-constrained work. <\/p>\n\n<p class=\"wp-block-paragraph\"><em>Note on naming: the Dakota portable flaw detector range has been updated. The <strong>FX71-DL<\/strong> model is the current development of the <strong>FX70-DL<\/strong> and retains the same DFX-7+ platform with firmware updates. The official Dakota P\/N is Z-221-0005.  <\/em><\/p>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"700\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia.jpg?resize=700%2C700&#038;ssl=1\" alt=\"Dakota FX70 Flaw Detector family - flaw detector range\" class=\"wp-image-222\" style=\"width:600px;height:auto\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia.jpg?w=700&amp;ssl=1 700w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia.jpg?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia.jpg?resize=150%2C150&amp;ssl=1 150w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n<h2 id=\"duplice-funzionalita\" class=\"wp-block-heading\">Dual functionality: flaw detector + thickness gauge<\/h2>\n\n<h3 class=\"wp-block-heading\">Flaw Detector mode<\/h3>\n\n<p class=\"wp-block-paragraph\">Configured as a flaw detector, the FX70-DL makes it possible to <strong>determine the size and position of flaws<\/strong> in materials and welded joints, and to <strong>differentiate between flaw types<\/strong> through A-Scan waveform analysis. It supports normal probes (0\u00b0) and angle beam transducers for weld inspection to AWS D1.1, EN ISO 17640, ASME Sect. V.  <\/p>\n\n<h3 class=\"wp-block-heading\">Thickness Gauge mode<\/h3>\n\n<p class=\"wp-block-paragraph\">Configuring the FX70-DL as a thickness gauge makes it possible to carry out simultaneous measurements of <strong>coating and base material thickness<\/strong> \u2014 an advanced capability that normally requires separate instruments.<\/p>\n\n<h2 id=\"quando-scegliere\" class=\"wp-block-heading\">When to choose the Dakota FX70-DL<\/h2>\n\n<h2 id=\"modalita-misura\" class=\"wp-block-heading\">Flaw detection modes<\/h2>\n\n<p class=\"wp-block-paragraph\">The FX70-DL offers <strong>five configurable detection modes<\/strong>:<\/p>\n\n<h3 class=\"wp-block-heading\">Zero Crossing<\/h3>\n\n<p class=\"wp-block-paragraph\">The gate detects the flank of the pulse but the measurement is taken at the next crossing of the X axis. This is the most common mode in ultrasonic measurement because of its stability against amplitude variations.<\/p>\n\n<h3 class=\"wp-block-heading\">Flank<\/h3>\n\n<p class=\"wp-block-paragraph\">The gate is triggered by the flank of the pulse on the graph and the measurement is taken at that exact point. Indicated when maximum time resolution is required. <\/p>\n\n<h3 class=\"wp-block-heading\">Peak<\/h3>\n\n<p class=\"wp-block-paragraph\">The gate is triggered by the intersection with the A-Scan pulse and detection is taken at the next peak of the signal (when it stops rising and begins to fall).<\/p>\n\n<h3 class=\"wp-block-heading\">TRIG<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>TRIG<\/strong> (Trigonometric) mode allows <strong>2D flaw location<\/strong> in terms of surface distance and depth. Used with <strong>angle beam transducers<\/strong>, it displays the beam path, depth and surface distance graphically and applies <strong>curved surface correction<\/strong>. Essential for weld inspection to AWS D1.1.  <\/p>\n\n<h3 class=\"wp-block-heading\">DAC (Distance Amplitude Correction)<\/h3>\n\n<p class=\"wp-block-paragraph\">Distance-amplitude correction for creating <strong>DAC curves<\/strong> that give the operator a sensitivity reference against flaws of known size at different distances. Essential for classifying detected flaws against the acceptance criteria of AWS, ASME and ISO. <\/p>\n\n<h3 class=\"wp-block-heading\">TCG (Time Corrected Gain)<\/h3>\n\n<p class=\"wp-block-paragraph\">TCG automatically increases gain as distance increases in order to obtain <strong>uniform sensitivity<\/strong> for the same reflector at different depths. The FX70-DL applies TCG automatically to compensate for ultrasonic attenuation through the material, extending performance on heavy wall thicknesses. <\/p>\n\n<h2 id=\"caratteristiche\" class=\"wp-block-heading\">Main features<\/h2>\n\n<ul class=\"wp-block-list\">\n<li><strong>2-in-1 platform<\/strong>: flaw detector + thickness gauge<\/li>\n\n\n\n<li><strong>5 detection modes<\/strong>: Zero Crossing, Flank, Peak, TRIG, DAC<\/li>\n\n\n\n<li><strong>Automatic TCG<\/strong> for attenuation compensation<\/li>\n\n\n\n<li><strong>Customisable toolkits<\/strong> for different applications<\/li>\n\n\n\n<li><strong>A-Scan display<\/strong> (standard flaw detector)<\/li>\n\n\n\n<li><strong>Cross-sectional B-Scan display<\/strong><\/li>\n\n\n\n<li><strong>4 GB memory<\/strong> with A-Scan and B-Scan archiving in batches<\/li>\n\n\n\n<li><strong>Alphanumeric batches<\/strong> with full data logging<\/li>\n\n\n\n<li><strong>Configurable pass\/fail limits<\/strong> with audible\/visual alarms<\/li>\n\n\n\n<li><strong>Thickness measurement capability<\/strong> with coating and material simultaneously<\/li>\n\n\n\n<li><strong>USB transfer<\/strong> to PC with DakMaster\u2122 software<\/li>\n\n\n\n<li><strong>Firmware update<\/strong> via USB\/DakMaster\u2122<\/li>\n\n\n\n<li><strong>Hybrid power supply<\/strong>: 3 \u00d7 AA or USB<\/li>\n\n\n\n<li><strong>Battery life<\/strong>: 12 hours on alkaline cells<\/li>\n\n\n\n<li><strong>Temperature range<\/strong>: -10 \u00f7 +60 \u00b0C<\/li>\n\n\n\n<li>Compact body <strong>397 g<\/strong><\/li>\n\n\n\n<li><strong>NIST-traceable calibration certificate<\/strong> supplied as standard<\/li>\n\n\n\n<li><strong>EN 12668-1 compliance<\/strong> (European standard for flaw detectors)<\/li>\n<\/ul>\n\n<h2 id=\"specifiche\" class=\"wp-block-heading\">Technical specifications<\/h2>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Parameter<\/strong><\/td><td><strong>Value<\/strong><\/td><\/tr><tr><td>Part Number<\/td><td>Z-221-0005<\/td><\/tr><tr><td>Technical designation<\/td><td>DFX-7+ (evoluzione FX71-DL)<\/td><\/tr><tr><td>Function<\/td><td>Flaw Detector + Thickness Gauge<\/td><\/tr><tr><td>Detection modes<\/td><td>Zero Crossing, Flank, Peak, TRIG, DAC<\/td><\/tr><tr><td>Time Corrected Gain<\/td><td>Yes, automatic<\/td><\/tr><tr><td>A-Scan<\/td><td>Yes<\/td><\/tr><tr><td>B-Scan<\/td><td>Yes<\/td><\/tr><tr><td>Memory<\/td><td>4 GB internal<\/td><\/tr><tr><td>Logging<\/td><td>Alphanumeric batches with A-Scan\/B-Scan for every measurement<\/td><\/tr><tr><td>Pass\/fail limits<\/td><td>Configurable with alarms<\/td><\/tr><tr><td>Data output<\/td><td>USB a PC<\/td><\/tr><tr><td>Software<\/td><td>DakMaster\u2122<\/td><\/tr><tr><td>Firmware update<\/td><td>Via USB<\/td><\/tr><tr><td>Operating temperature<\/td><td>-10 \u00f7 +60 \u00b0C (14 \u00f7 140 \u00b0F)<\/td><\/tr><tr><td>Power supply<\/td><td>3 \u00d7 AA + via USB<\/td><\/tr><tr><td>Battery life<\/td><td>12 h alkaline \/ 5 h NiCd \/ 12 h NiMH<\/td><\/tr><tr><td>Weight<\/td><td>397 g (with batteries)<\/td><\/tr><tr><td>Dimensions<\/td><td>63.5 \u00d7 165 \u00d7 31.5 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"ndt-torna-su wp-block-paragraph\"><a href=\"#indice\">\u2191 Back to index<\/a><\/p>\n\n<h2 id=\"applicazioni\" class=\"wp-block-heading\">Typical applications<\/h2>\n\n<ul class=\"wp-block-list\">\n<li><strong>Structural weld inspection<\/strong> to AWS D1.1, ISO 17640, ASME Sect. V <\/li>\n\n\n\n<li><strong>Production quality control<\/strong> of castings, forgings and plate<\/li>\n\n\n\n<li><strong>Predictive maintenance<\/strong> of pressure vessels, piping and heat exchangers<\/li>\n\n\n\n<li><strong>Inspection of welded structures<\/strong>: bridges, tanks, offshore platforms<\/li>\n\n\n\n<li><strong>Aerospace industry<\/strong>: inspection of structural components<\/li>\n\n\n\n<li><strong>Rail sector<\/strong>: inspection of rails, axles and welds<\/li>\n\n\n\n<li><strong>Automotive industry<\/strong>: integrity checks on structural parts<\/li>\n\n\n\n<li><strong>Infrastructure maintenance<\/strong>: pipelines, dams, steel structures<\/li>\n\n\n\n<li><strong>Fatigue crack detection<\/strong><\/li>\n\n\n\n<li><strong>Flaw characterisation<\/strong> (shape\/size classification)<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Recommended application guides:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ultrasuonindt.it\/en\/ultrasonic-weld-inspection-to-aws-d1-1-with-the-dakota-fx70-dl\/\">Ultrasonic weld inspection to AWS D1.1 with the Dakota FX70-DL<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/ultrasuonindt.it\/en\/aws-d1-1-and-ultrasonic-weld-inspection-requirements-and-instruments\/\">AWS D1.1 and ultrasonic weld inspection: requirements and instruments<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/ultrasuonindt.it\/en\/api-570-and-api-653-instrumentation-requirements-for-piping-and-tank-inspection\/\">API 570 and API 653: instrumentation requirements<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/ultrasuonindt.it\/en\/how-to-choose-the-right-ultrasonic-transducer-for-every-application\/\">How to choose the right ultrasonic transducer<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/ultrasuonindt.it\/en\/data-logger-vs-manual-recording-why-ndt-readings-should-be-archived\/\">Data logger vs manual recording<\/a><\/li>\n<\/ul>\n\n<h2 id=\"fornitura\" class=\"wp-block-heading\">Scope of supply<\/h2>\n\n<ul class=\"wp-block-list\">\n<li>Dakota FX70-DL \/ FX71-DL instrument<\/li>\n\n\n\n<li>Ultrasonic couplant<\/li>\n\n\n\n<li>User manual<\/li>\n\n\n\n<li>Rigid carrying case<\/li>\n\n\n\n<li>NIST traceable calibration certificate<\/li>\n\n\n\n<li>3 AA batteries<\/li>\n\n\n\n<li>USB cable<\/li>\n\n\n\n<li>DakMaster\u2122 software<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><em>Note: the probe is not included in the standard kit. For sizing the optimum probe for Your application (weld inspection, crack detection, thickness measurement), <a href=\"https:\/\/ultrasuonindt.it\/en\/contact\/\">contact us<\/a>. <\/em><\/p>\n\n<div id=\"codici-ordine\" class=\"wp-block-group ndt-catalogo-ordine is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-color\" style=\"color:#225f78\">Order codes: instrument, probes and accessories<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Below you will find everything you can order for the FX71-DL: the instrument, compatible probes, couplants, calibration blocks and accessories. Please quote the <strong>order code<\/strong> in your request: it is the code shown on the quotation and on the order confirmation. <\/p>\n\n\n\n<div class=\"wp-block-group has-background is-layout-constrained wp-container-core-group-is-layout-4e7c7061 wp-block-group-is-layout-constrained\" style=\"border-left-color:#225f78;border-left-width:6px;background-color:#ebf1f4;padding-top:16px;padding-right:24px;padding-bottom:16px;padding-left:24px\">\n<p class=\"has-text-color wp-block-paragraph\" style=\"color:#225f78;font-style:italic;font-weight:400\">The probe is <strong>not included<\/strong> with the instrument: it must be chosen and ordered separately from those listed on this page. All probes in the table are compatible with the FX71-DL. <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group ndt-catalogo-blocco is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-text-color\" style=\"color:#225f78\">Instrument<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Supplied with: FX71-DL instrument, ultrasonic couplant, manual, plastic carrying case, calibration certificate, AA batteries, PC software and data transfer cable. Probe not included. <\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>Image<\/th><th>Order code<\/th><th>SKU<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-26-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"FX71-DL portable flaw detector (DFX-7+)\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>Z-221-0005<\/strong><\/td><td>10-16-26<\/td><td>Difettoscopio portatile FX71-DL (DFX-7+)<br\/><em>Probe to be ordered separately<\/em><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group ndt-catalogo-blocco is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-text-color\" style=\"color:#225f78\">Compatible probes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Flaw detection probes: single-element contact probes (Hi-Wear and Finger Tip) for longitudinal waves, Standard and Quick Change shear-wave angle probes (these require the wedge, see below) and integral probes for welds. Frequency and size are chosen according to the thickness and geometry of the part. <\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>Image<\/th><th>Order code<\/th><th>SKU<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-38-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Hi-Wear, composite crystal, 1 MHz, &#xD8; 1\/2\" bnc=\"\" connector=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8040-0868<\/strong><\/td><td>10-16-38<\/td><td>Single-element contact probe Hi-Wear, composite crystal, 1 MHz, \u00d8 1\/2&#8243;, BNC connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-39-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Hi-Wear, composite crystal, 1 MHz, &#xD8; 1\" connector=\"\" bnc=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8070-0868<\/strong><\/td><td>10-16-39<\/td><td>Single-element contact probe Hi-Wear, composite crystal, 1 MHz, \u00d8 1&#8243;, connector BNC<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-40-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Hi-Wear, composite crystal, 2.25 MHz, &#xD8; 1\/2\" connector=\"\" bnc=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8040-1878<\/strong><\/td><td>10-16-40<\/td><td>Single-element contact probe Hi-Wear, composite crystal, 2.25 MHz, \u00d8 1\/2&#8243;, BNC connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-41-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Hi-Wear, composite crystal, 2.25 MHz, &#xD8; 1\" connector=\"\" bnc=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8070-1878<\/strong><\/td><td>10-16-41<\/td><td>Single-element contact probe Hi-Wear, composite crystal, 2.25 MHz, \u00d8 1&#8243;, BNC connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-42-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Hi-Wear, composite crystal, 5 MHz, &#xD8; 1\/2\" connector=\"\" bnc=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8040-2878<\/strong><\/td><td>10-16-42<\/td><td>Single-element contact probe Hi-Wear, composite crystal, 5 MHz, \u00d8 1\/2&#8243;, BNC connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-43-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Hi-Wear, composite crystal, 5 MHz, &#xD8; 1\" connector=\"\" bnc=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8070-2878<\/strong><\/td><td>10-16-43<\/td><td>Single-element contact probe Hi-Wear, composite crystal, 5 MHz, \u00d8 1&#8243;, BNC connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-70-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip, 2.25 MHz, &#xD8; 1\/4\" connector=\"\" microdot=\"\" side=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-4023-1855<\/strong><\/td><td>10-15-70<\/td><td>Single-element contact probe Finger Tip, 2.25 MHz, \u00d8 1\/4&#8243;, connector Microdot, side exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-69-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip, 2.25 MHz, &#xD8; 3\/8\" connector=\"\" microdot=\"\" side=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-4033-1855<\/strong><\/td><td>10-15-69<\/td><td>Single-element contact probe Finger Tip, 2.25 MHz, \u00d8 3\/8&#8243;, connector Microdot, side exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-71-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip, 2.25 MHz, &#xD8; 1\/2\" connector=\"\" microdot=\"\" side=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-4043-1855<\/strong><\/td><td>10-15-71<\/td><td>Single-element contact probe Finger Tip, 2.25 MHz, \u00d8 1\/2&#8243;, connector Microdot, side exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-56-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip, 5 MHz, &#xD8; 1\/4\" connector=\"\" microdot=\"\" side=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-4023-2855<\/strong><\/td><td>10-15-56<\/td><td>Single-element contact probe Finger Tip, 5 MHz, \u00d8 1\/4&#8243;, connector Microdot, side exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-72-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip, 5 MHz, &#xD8; 3\/8\" connector=\"\" microdot=\"\" side=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-4033-2855<\/strong><\/td><td>10-15-72<\/td><td>Single-element contact probe Finger Tip, 5 MHz, \u00d8 3\/8&#8243;, connector Microdot, side exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-73-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip, 5 MHz, &#xD8; 1\/2\" connector=\"\" microdot=\"\" side=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-4043-2855<\/strong><\/td><td>10-15-73<\/td><td>Single-element contact probe Finger Tip, 5 MHz, \u00d8 1\/2&#8243;, connector Microdot, side exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-57-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip, 10 MHz, &#xD8; 1\/4\" connector=\"\" microdot=\"\" side=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-4023-4855<\/strong><\/td><td>10-15-57<\/td><td>Single-element contact probe Finger Tip, 10 MHz, \u00d8 1\/4&#8243;, Microdot connector, side exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-58-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip, 10 MHz, &#xD8; 1\/2\" connector=\"\" microdot=\"\" side=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-4043-4855<\/strong><\/td><td>10-15-58<\/td><td>Single-element contact probe Finger Tip, 10 MHz, \u00d8 1\/2&#8243;, connector Microdot, side exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-75-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip Slim Line (non-magnetic), 5 MHz, &#xD8; 1\/8\" connector=\"\" microdot=\"\" top=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-5903-2875<\/strong><\/td><td>10-15-75<\/td><td>Single-element contact probe Finger Tip Slim Line (non-magnetic), 5 MHz, \u00d8 1\/8&#8243;, connector Microdot, top exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-76-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Single-element contact probe Finger Tip Slim Line, 10 MHz, &#xD8; 1\/8\" connector=\"\" microdot=\"\" top=\"\" exit=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-5903-4875<\/strong><\/td><td>10-15-76<\/td><td>Single-element contact probe Finger Tip Slim Line, 10 MHz, \u00d8 1\/8&#8243;, connector Microdot, top exit<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-44-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Standard (SS) High-Gain &#x2013; requires separate wedge, 2.25 MHz, 1\/2\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8044-1848<\/strong><\/td><td>10-16-44<\/td><td>Angle-beam shear-wave probe Standard (SS) High-Gain \u2013 requires separate wedge, 2.25 MHz, 1\/2&#8243; x 1\/2&#8243;<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-45-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Standard (SS) High-Gain &#x2013; requires separate wedge, 2.25 MHz, 5\/8\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8054-1848<\/strong><\/td><td>10-16-45<\/td><td>Angle-beam shear-wave probe Standard (SS) High-Gain \u2013 requires separate wedge, 2.25 MHz, 5\/8&#8243; x 5\/8&#8243;<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-46-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Standard (SS) High-Gain &#x2013; requires separate wedge, 5 MHz, 1\/2\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8044-2848<\/strong><\/td><td>10-16-46<\/td><td>Angle-beam shear-wave probe Standard (SS) High-Gain \u2013 requires separate wedge, 5 MHz, 1\/2&#8243; x 1\/2&#8243;<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-47-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Standard (SS) High-Gain &#x2013; requires separate wedge, 5 MHz, 5\/8\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-8054-2848<\/strong><\/td><td>10-16-47<\/td><td>Angle-beam shear-wave probe Standard (SS) High-Gain \u2013 requires separate wedge, 5 MHz, 5\/8&#8243; x 5\/8&#8243;<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-57-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Quick Change (QC) High-Gain &#x2013; requires separate wedge, 2.25 MHz, &#xD8; 3\/8\" microdot=\"\" connector=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-5035-1845<\/strong><\/td><td>10-16-57<\/td><td>Angle-beam shear-wave probe Quick Change (QC) High-Gain \u2013 requires separate wedge, 2.25 MHz, \u00d8 3\/8&#8243;, Microdot connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-58-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Quick Change (QC) High-Gain &#x2013; requires separate wedge, 2.25 MHz, &#xD8; 1\/2\" microdot=\"\" connector=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-5045-1845<\/strong><\/td><td>10-16-58<\/td><td>Angle-beam shear-wave probe Quick Change (QC) High-Gain \u2013 requires separate wedge, 2.25 MHz, \u00d8 1\/2&#8243;, Microdot connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-59-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Quick Change (QC) High-Gain &#x2013; requires separate wedge, 5 MHz, &#xD8; 1\/4\" microdot=\"\" connector=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-5025-2845<\/strong><\/td><td>10-16-59<\/td><td>Angle-beam shear-wave probe Quick Change (QC) High-Gain \u2013 requires separate wedge, 5 MHz, \u00d8 1\/4&#8243;, Microdot connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-60-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Quick Change (QC) High-Gain &#x2013; requires separate wedge, 5 MHz, &#xD8; 3\/8\" microdot=\"\" connector=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-5035-2845<\/strong><\/td><td>10-16-60<\/td><td>Angle-beam shear-wave probe Quick Change (QC) High-Gain \u2013 requires separate wedge, 5 MHz, \u00d8 3\/8&#8243;, Microdot connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-61-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Quick Change (QC) High-Gain &#x2013; requires separate wedge, 5 MHz, &#xD8; 1\/2\" microdot=\"\" connector=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-5045-2845<\/strong><\/td><td>10-16-61<\/td><td>Angle-beam shear-wave probe Quick Change (QC) High-Gain \u2013 requires separate wedge, 5 MHz, \u00d8 1\/2&#8243;, Microdot connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-62-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Angle-beam shear-wave probe Quick Change (QC) High-Gain &#x2013; requires separate wedge, 10 MHz, &#xD8; 1\/4\" microdot=\"\" connector=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T-5025-4845<\/strong><\/td><td>10-16-62<\/td><td>Angle-beam shear-wave probe Quick Change (QC) High-Gain \u2013 requires separate wedge, 10 MHz, \u00d8 1\/4&#8243;, Microdot connector<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-97-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Integral-wedge shear-wave probe 4 MHz, 45&#xB0;, &#xD8; 10 mm, Lemo 00 &#x2013; weld inspection \/ prove-up\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>TF4M0045<\/strong><\/td><td>10-15-97<\/td><td>Integral-wedge shear-wave probe 4 MHz, 45\u00b0, \u00d8 10 mm, Lemo 00 \u2013 weld inspection \/ prove-up<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-73-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Integral-wedge shear-wave probe 4 MHz, 70&#xB0;, &#xD8; 10 mm, Lemo 00 &#x2013; weld inspection\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>TF4M0070<\/strong><\/td><td>10-16-73<\/td><td>Integral-wedge shear-wave probe 4 MHz, 70\u00b0, \u00d8 10 mm, Lemo 00 \u2013 weld inspection<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/segnaposto-product_image_coming_soon.webp?resize=90%2C90&#038;ssl=1\" alt=\"Image coming soon\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>TF5M00F<\/strong><\/td><td>10-16-74<\/td><td>Dual-element probe 5 MHz, 0\u00b0, \u00d8 10 mm, Lemo 00, short focus \u2013 weld lamination testing<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group ndt-catalogo-blocco is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-text-color\" style=\"color:#225f78\">Wedges<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wedges for angle-beam probes: choose the angle and the size of the probe in use.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>Image<\/th><th>Order code<\/th><th>SKU<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-48-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard wedge for Standard (SS) shear-wave probes, 45&#xB0;, 1\/2\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0014<\/strong><\/td><td>10-16-48<\/td><td>Standard wedge for Standard (SS) shear-wave probes, 45\u00b0, 1\/2&#8243; x 1\/2&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-49-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard wedge for Standard (SS) shear-wave probes, 45&#xB0;, 5\/8\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0020<\/strong><\/td><td>10-16-49<\/td><td>Standard wedge for Standard (SS) shear-wave probes, 45\u00b0, 5\/8&#8243; x 5\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-50-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard wedge for Standard (SS) shear-wave probes, 60&#xB0;, 1\/2\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0015<\/strong><\/td><td>10-16-50<\/td><td>Standard wedge for Standard (SS) shear-wave probes, 60\u00b0, 1\/2&#8243; x 1\/2&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-51-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard wedge for Standard (SS) shear-wave probes, 60&#xB0;, 5\/8\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0021<\/strong><\/td><td>10-16-51<\/td><td>Standard wedge for Standard (SS) shear-wave probes, 60\u00b0, 5\/8&#8243; x 5\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-52-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard wedge for Standard (SS) shear-wave probes, 70&#xB0;, 1\/2\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0016<\/strong><\/td><td>10-16-52<\/td><td>Standard wedge for Standard (SS) shear-wave probes, 70\u00b0, 1\/2&#8243; x 1\/2&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-53-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard wedge for Standard (SS) shear-wave probes, 70&#xB0;, 5\/8\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0022<\/strong><\/td><td>10-16-53<\/td><td>Standard wedge for Standard (SS) shear-wave probes, 70\u00b0, 5\/8&#8243; x 5\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-54-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Snail-type (AWS) wedge for Standard (SS) shear-wave probes, 45&#xB0;, 5\/8\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0023<\/strong><\/td><td>10-16-54<\/td><td>Snail-type (AWS) wedge for Standard (SS) shear-wave probes, 45\u00b0, 5\/8&#8243; x 5\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-55-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Snail-type (AWS) wedge for Standard (SS) shear-wave probes, 60&#xB0;, 5\/8\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0024<\/strong><\/td><td>10-16-55<\/td><td>Snail-type (AWS) wedge for Standard (SS) shear-wave probes, 60\u00b0, 5\/8&#8243; x 5\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-56-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Snail-type (AWS) wedge for Standard (SS) shear-wave probes, 70&#xB0;, 5\/8\" x=\"\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0025<\/strong><\/td><td>10-16-56<\/td><td>Snail-type (AWS) wedge for Standard (SS) shear-wave probes, 70\u00b0, 5\/8&#8243; x 5\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-63-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard Quick Change wedge for QC shear-wave probes, 45&#xB0;, &#xD8; 1\/4\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0038<\/strong><\/td><td>10-16-63<\/td><td>Standard Quick Change wedge for QC shear-wave probes, 45\u00b0, \u00d8 1\/4&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-64-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard Quick Change wedge for QC shear-wave probes, 45&#xB0;, &#xD8; 3\/8\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0041<\/strong><\/td><td>10-16-64<\/td><td>Standard Quick Change wedge for QC shear-wave probes, 45\u00b0, \u00d8 3\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-65-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard Quick Change wedge for QC shear-wave probes, 45&#xB0;, &#xD8; 1\/2\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0044<\/strong><\/td><td>10-16-65<\/td><td>Standard Quick Change wedge for QC shear-wave probes, 45\u00b0, \u00d8 1\/2&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-67-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard Quick Change wedge for QC shear-wave probes, 60&#xB0;, &#xD8; 3\/8\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0042<\/strong><\/td><td>10-16-67<\/td><td>Standard Quick Change wedge for QC shear-wave probes, 60\u00b0, \u00d8 3\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-68-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard Quick Change wedge for QC shear-wave probes, 60&#xB0;, &#xD8; 1\/2\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0045<\/strong><\/td><td>10-16-68<\/td><td>Standard Quick Change wedge for QC shear-wave probes, 60\u00b0, \u00d8 1\/2&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-69-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard Quick Change wedge for QC shear-wave probes, 70&#xB0;, &#xD8; 1\/4\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0040<\/strong><\/td><td>10-16-69<\/td><td>Standard Quick Change wedge for QC shear-wave probes, 70\u00b0, \u00d8 1\/4&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-70-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard Quick Change wedge for QC shear-wave probes, 70&#xB0;, &#xD8; 3\/8\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0043<\/strong><\/td><td>10-16-70<\/td><td>Standard Quick Change wedge for QC shear-wave probes, 70\u00b0, \u00d8 3\/8&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-71-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Standard Quick Change wedge for QC shear-wave probes, 70&#xB0;, &#xD8; 1\/2\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>X-004-0046<\/strong><\/td><td>10-16-71<\/td><td>Standard Quick Change wedge for QC shear-wave probes, 70\u00b0, \u00d8 1\/2&#8243;<br\/><em>Wedge only: probe NOT included<\/em><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group ndt-catalogo-blocco is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-text-color\" style=\"color:#225f78\">Probe cables<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cables connecting single-element probes to the instrument.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>Image<\/th><th>Order code<\/th><th>SKU<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/14-16-00-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Probe cable 1.2 m single Lemo 00 &#x2013; Microdot\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>N-104-0020<\/strong><\/td><td>14-16-00<\/td><td>Probe cable 1.2 m single Lemo 00 \u2013 Microdot<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-19-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Probe cable 1.2 m single Lemo 00 &#x2013; BNC\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>N-104-0070<\/strong><\/td><td>10-16-19<\/td><td>Probe cable 1.2 m single Lemo 00 \u2013 BNC<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-03-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Probe cable 1.2 m single Lemo 00 &#x2013; Lemo 00 (prove-up probes)\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>N-104-0000<\/strong><\/td><td>10-16-03<\/td><td>Probe cable 1.2 m single Lemo 00 \u2013 Lemo 00 (prove-up probes)<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-20-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Probe cable 1.2 m dual Lemo &#x2013; Microdot\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>N-204-0020<\/strong><\/td><td>10-16-20<\/td><td>Probe cable 1.2 m dual Lemo \u2013 Microdot<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-22-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Probe cable 1.2 m dual Lemo &#x2013; Lemo\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>N-204-0000<\/strong><\/td><td>10-16-22<\/td><td>Probe cable 1.2 m dual Lemo \u2013 Lemo<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-16-75-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Probe cable 1.5 m Lemo 00 &#x2013; Lemo 00\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>TL-31897-60<\/strong><\/td><td>10-16-75<\/td><td>Probe cable 1.5 m Lemo 00 \u2013 Lemo 00<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group ndt-catalogo-blocco is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-text-color\" style=\"color:#225f78\">Couplants<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A couplant is included in the supply; for refills and for high temperatures, choose from the following.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>Image<\/th><th>Order code<\/th><th>SKU<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/12-13-50-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Yellow anti-rust couplant gel, RCCM compliant. Standard temperature range 0 \/ 80 &#xB0;C. 500 ml pack\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>GEL-ACC-STD<\/strong><\/td><td>12-13-50<\/td><td>Yellow anti-rust couplant gel, RCCM compliant. Standard temperature range 0 \/ 80 \u00b0C. 500 ml pack  <\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/12-13-51-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Blue anti-corrosion couplant gel, RCCM compliant. Extended temperature range -20 \/ 120 &#xB0;C. 500 ml pack\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>GEL-ACC-EXT<\/strong><\/td><td>12-13-51<\/td><td>Blue anti-corrosion couplant gel, RCCM compliant. Extended temperature range -20 \/ 120 \u00b0C. 500 ml pack  <\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/12-13-53-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Special very-high-temperature ultrasonic coupling paste +100 \/ 520 &#xB0;C. Non-flammable and smoke-free. RCCM compliant. 200 g pack\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>PST-ACC-UHT<\/strong><\/td><td>12-13-53<\/td><td>Special very-high-temperature ultrasonic coupling paste +100 \/ 520 \u00b0C. Non-flammable and smoke-free. RCCM compliant. 200 g pack   <\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-82-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"High-temperature ultrasonic couplant (370 &#xB0;C), 60 ml\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T92024034-9<\/strong><\/td><td>10-15-82<\/td><td>High-temperature ultrasonic couplant (370 \u00b0C), 60 ml<\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-83-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"High-temperature ultrasonic couplant (370 &#xB0;C), 60 ml, pack of 2\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>T92024034-10<\/strong><\/td><td>10-15-83<\/td><td>High-temperature ultrasonic couplant (370 \u00b0C), 60 ml, pack of 2<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group ndt-catalogo-blocco is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-text-color\" style=\"color:#225f78\">Accessories and spare parts<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cases, cables and accessories specific to this instrument.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>Image<\/th><th>Order code<\/th><th>SKU<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-64-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Nylon instrument case (MX, PMX, CMX, MVX, PVX, MMX, FX71, BT1 \/ MINI-MAX)\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>F-149-0001<\/strong><\/td><td>10-15-64<\/td><td>Nylon instrument case (MX, PMX, CMX, MVX, PVX, MMX, FX71, BT1 \/ MINI-MAX)<br\/><em>Case only: instrument NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-65-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Rubber instrument boot (MX, PMX, CMX, MVX, PVX, MMX, FX71, BT1- DL v2.0)\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>A-149-6002<\/strong><\/td><td>10-15-65<\/td><td>Rubber instrument boot (MX, PMX, CMX, MVX, PVX, MMX, FX71, BT1- DL v2.0)<br\/><em>Case only: instrument NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/10-15-66-main.webp?resize=90%2C90&#038;ssl=1\" alt=\"Plastic carrying case (MX, PMX, CMX, MVX, PVX, MMX, FX71, BT1)\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>A-100-6003<\/strong><\/td><td>10-15-66<\/td><td>Plastic carrying case (MX, PMX, CMX, MVX, PVX, MMX, FX71, BT1)<br\/><em>Case only: instrument NOT included<\/em><\/td><\/tr><tr><td><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/10\/segnaposto-product_image_coming_soon.webp?resize=90%2C90&#038;ssl=1\" alt=\"Image coming soon\" width=\"90\" height=\"90\" style=\"border:1px solid #000000;border-radius:15px\"\/><\/td><td><strong>N-003-0330<\/strong><\/td><td>10-15-39<\/td><td>USB-C \/ USB-A data cable 0.9 m (V2.0 instruments)<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n<p class=\"wp-block-paragraph\">For more on choosing the probe: <a href=\"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/transducers-for-ultrasonic-flaw-detectors\/\">probes for flaw detectors<\/a> and the guide <a href=\"https:\/\/ultrasuonindt.it\/en\/how-to-choose-the-right-ultrasonic-transducer-for-every-application\/\">How to choose the right ultrasonic transducer<\/a>. For a quotation, please state the order code and quantity. <\/p>\n\n<p class=\"ndt-torna-su wp-block-paragraph\"><a href=\"#indice\">\u2191 Back to index<\/a><\/p>\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 id=\"download\" class=\"wp-block-heading\">Documentation download<\/h2>\n\n<p class=\"wp-block-paragraph\">Official Dakota NDT technical documentation. Files open in a new tab.<\/p>\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><tbody><tr><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-datasheet_rilevatore_difetti_ultrasonico_fx71_dl.pdf\" target=\"_blank\" rel=\"noopener\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=48%2C61&#038;ssl=1\" alt=\"Download PDF\" width=\"48\" height=\"61\" class=\"wp-image-1605\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?w=433&amp;ssl=1 433w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=236%2C300&amp;ssl=1 236w\" sizes=\"auto, (max-width: 48px) 100vw, 48px\" \/><\/a><\/td><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-datasheet_rilevatore_difetti_ultrasonico_fx71_dl.pdf\" target=\"_blank\" rel=\"noopener\"><strong>FX71-DL datasheet<\/strong><\/a><\/td><td>Datasheet<\/td><\/tr><tr><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-manuale_uso_rilevatore_difetti_ultrasonico_modalita_misura_spessore_fx70_dl.pdf\" target=\"_blank\" rel=\"noopener\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=48%2C61&#038;ssl=1\" alt=\"Download PDF\" width=\"48\" height=\"61\" class=\"wp-image-1605\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?w=433&amp;ssl=1 433w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=236%2C300&amp;ssl=1 236w\" sizes=\"auto, (max-width: 48px) 100vw, 48px\" \/><\/a><\/td><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-manuale_uso_rilevatore_difetti_ultrasonico_modalita_misura_spessore_fx70_dl.pdf\" target=\"_blank\" rel=\"noopener\"><strong>FX70-DL user manual \u2014 thickness measurement mode<\/strong><\/a><\/td><td>Manual<\/td><\/tr><tr><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-manuale_uso_rilevatore_difetti_ultrasonico_modalita_rilevamento_difetti_fx70_dl.pdf\" target=\"_blank\" rel=\"noopener\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=48%2C61&#038;ssl=1\" alt=\"Download PDF\" width=\"48\" height=\"61\" class=\"wp-image-1605\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?w=433&amp;ssl=1 433w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=236%2C300&amp;ssl=1 236w\" sizes=\"auto, (max-width: 48px) 100vw, 48px\" \/><\/a><\/td><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-manuale_uso_rilevatore_difetti_ultrasonico_modalita_rilevamento_difetti_fx70_dl.pdf\" target=\"_blank\" rel=\"noopener\"><strong>FX70-DL user manual \u2014 flaw detection mode<\/strong><\/a><\/td><td>Manual<\/td><\/tr><tr><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-lettera_conformita_rilevatore_difetti_ultrasonico_fx70_dl_fx71_dl.pdf\" target=\"_blank\" rel=\"noopener\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=48%2C61&#038;ssl=1\" alt=\"Download PDF\" width=\"48\" height=\"61\" class=\"wp-image-1605\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?w=433&amp;ssl=1 433w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=236%2C300&amp;ssl=1 236w\" sizes=\"auto, (max-width: 48px) 100vw, 48px\" \/><\/a><\/td><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-lettera_conformita_rilevatore_difetti_ultrasonico_fx70_dl_fx71_dl.pdf\" target=\"_blank\" rel=\"noopener\"><strong>Letter of conformity \u2014 FX70-DL \/ FX71-DL<\/strong><\/a><\/td><td>Compliance<\/td><\/tr><tr><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-rapporto_test_emc_en_rilevatore_difetti_ultrasonico_fx70_dl_fx71_dl.pdf\" target=\"_blank\" rel=\"noopener\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=48%2C61&#038;ssl=1\" alt=\"Download PDF\" width=\"48\" height=\"61\" class=\"wp-image-1605\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?w=433&amp;ssl=1 433w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=236%2C300&amp;ssl=1 236w\" sizes=\"auto, (max-width: 48px) 100vw, 48px\" \/><\/a><\/td><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-rapporto_test_emc_en_rilevatore_difetti_ultrasonico_fx70_dl_fx71_dl.pdf\" target=\"_blank\" rel=\"noopener\"><strong>EMC test report (EN \u2014 Europe) \u2014 FX70-DL \/ FX71-DL<\/strong><\/a><\/td><td>EMC EN<\/td><\/tr><tr><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-rapporto_test_emc_fcc_rilevatore_difetti_ultrasonico_fx70_dl_fx71_dl.pdf\" target=\"_blank\" rel=\"noopener\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=48%2C61&#038;ssl=1\" alt=\"Download PDF\" width=\"48\" height=\"61\" class=\"wp-image-1605\" srcset=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?w=433&amp;ssl=1 433w, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/icona_pdf_download.webp?resize=236%2C300&amp;ssl=1 236w\" sizes=\"auto, (max-width: 48px) 100vw, 48px\" \/><\/a><\/td><td><a href=\"https:\/\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota-documentazione-rapporto_test_emc_fcc_rilevatore_difetti_ultrasonico_fx70_dl_fx71_dl.pdf\" target=\"_blank\" rel=\"noopener\"><strong>EMC test report (FCC \u2014 USA) \u2014 FX70-DL \/ FX71-DL<\/strong><\/a><\/td><td>EMC FCC<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\">\n<li><strong>Weld inspection<\/strong> with angle beam probes (AWS D1.1, ISO 17640)<\/li>\n\n\n\n<li><strong>Crack detection<\/strong> in steel structures<\/li>\n\n\n\n<li><strong>In-service inspection<\/strong> of critical components (pressure vessels, piping, welded structures)<\/li>\n\n\n\n<li>The need for <strong>a single instrument<\/strong> for flaw detection + thickness gauging<\/li>\n\n\n\n<li><strong>Infrastructure maintenance<\/strong>: bridges, pipelines, load-bearing structures<\/li>\n\n\n\n<li><strong>Production quality control<\/strong>: integrity checks on castings, forgings and welded parts<\/li>\n\n\n\n<li>Field inspections requiring a <strong>portable battery-powered instrument<\/strong><\/li>\n\n\n\n<li>Users requiring full <strong>EN 12668-1 compliance<\/strong> for certification<\/li>\n\n\n\n<li>Users requiring complete A-Scan + B-Scan archiving for reporting<\/li>\n<\/ul>\n\n<h2 id=\"normative\" class=\"wp-block-heading\">Standards and certifications<\/h2>\n\n<ul class=\"wp-block-list\">\n<li><strong>EN 12668-1<\/strong> \u2014 European standard for ultrasonic flaw detection equipment (compliance declared by Dakota)<\/li>\n\n\n\n<li><strong>NIST traceable factory calibration<\/strong><\/li>\n\n\n\n<li><strong>MIL-STD-45662A compliance<\/strong><\/li>\n\n\n\n<li><strong>CE marking<\/strong> and EMC compliance<\/li>\n\n\n\n<li>Thickness gauge mode compliant with <strong>ASTM E797<\/strong> and <strong>EN 14127<\/strong><\/li>\n\n\n\n<li><strong>Calibration certificate<\/strong> supplied as standard<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">For the regulatory framework see <a href=\"https:\/\/ultrasuonindt.it\/en\/ndt-standards-for-thickness-measurement-en-14127-astm-e797-and-en-15317\/\">NDT standards for thickness measurement<\/a> and <a href=\"https:\/\/ultrasuonindt.it\/en\/aws-d1-1-and-ultrasonic-weld-inspection-requirements-and-instruments\/\">AWS D1.1 and ultrasonic weld inspection<\/a>.<\/p>\n\n<h2 id=\"faq\" class=\"wp-block-heading\">Frequently asked questions<\/h2>\n\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-1757441000000\"><strong class=\"schema-faq-question\">Has the FX70-DL been replaced by the FX71-DL?<\/strong> <p class=\"schema-faq-answer\">The FX71-DL is the current development of the FX70-DL \/ DFX-7 platform with firmware and hardware updates. The Dakota commercial P\/N is now Z-221-0005 with the DFX-7+ designation. The features described on this page reflect the current version of the instrument.  <\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1757441001000\"><strong class=\"schema-faq-question\">What is the difference between the FX70-DL and the FX81-DL?<\/strong> <p class=\"schema-faq-answer\">The FX70-DL is portable (397 g, 3 \u00d7 AA, 63.5 \u00d7 165 \u00d7 31.5 mm) for field inspections. The <a href=\"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx81-dl-benchtop-flaw-detector\/\">FX81-DL<\/a> is a benchtop unit for laboratory or fixed-station inspection, with extended battery life and a larger display. Both share the DFX platform and the detection modes.  <\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1757441002000\"><strong class=\"schema-faq-question\">Is it EN 12668-1 compliant?<\/strong> <p class=\"schema-faq-answer\">Yes, the FX70-DL is declared <strong>EN 12668-1 compliant<\/strong> by Dakota. EN 12668-1 is the European reference standard for the characterisation and verification of ultrasonic flaw detection equipment and is required for certification in inspections to EN ISO 17640 and equivalent standards. <\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1757441003000\"><strong class=\"schema-faq-question\">Can I also use it as a thickness gauge?<\/strong> <p class=\"schema-faq-answer\">Yes. The FX70-DL is a 2-in-1 instrument: configured as a thickness gauge it measures material and coating thickness simultaneously. However, for thickness-only applications we recommend the dedicated gauges in the CMX, MX or PMX ranges, which offer ergonomics optimised for repetitive measurement.  <\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1757441004000\"><strong class=\"schema-faq-question\">What is the difference between TRIG and DAC?<\/strong> <p class=\"schema-faq-answer\">TRIG is a geometric function: it calculates the position and depth of flaws from angle beam probes by applying trigonometry to the beam path. DAC is an amplitude correction function: it creates sensitivity curves against distance in order to classify flaw size. The two are often used together when inspecting welds with angle beam probes.  <\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1757441005000\"><strong class=\"schema-faq-question\">Can I store A-Scans together with the measurements?<\/strong> <p class=\"schema-faq-answer\">Yes. With 4 GB of internal memory the FX70-DL stores the A-Scans and B-Scans associated with each measurement in alphanumeric batches. DakMaster\u2122 software makes it possible to review the waveforms in the laboratory for in-depth analysis and to generate professional reports.  <\/p> <\/div> <\/div>\n\n<p class=\"ndt-torna-su wp-block-paragraph\"><a href=\"#indice\">\u2191 Back to index<\/a><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Request a tailored quotation for the Dakota FX70-DL \/ FX71-DL<\/strong><br\/>We will help You choose the optimum probe for Your application (weld inspection, crack detection, thickness measurement) and configure the kit. <a href=\"https:\/\/ultrasuonindt.it\/en\/contact\/\">Contact us<\/a> for dedicated technical advice or to arrange a demonstration.<\/p>\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Further information and contacts <\/h5>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><a href=\"http:\/\/www.roder.it\">Systems division and sensor integration partner : www.roder.it<\/a><br\/><a href=\"https:\/\/ultrasuonindt.it\/chi-siamo\/\">More information about RODER SRL : about us<\/a><br\/>Contact for general information : <a href=\"mailto:info@roder.it\">info@roder.it<\/a><br\/>Contact for information about these products : <a href=\"mailto:info@roder.it\">info@roder.it<\/a><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><br\/>The information contained on this web page is provided for information purposes only. Although it has been compiled with the utmost care, it does not constitute a contractual offer or a binding commitment to supply. It may contain transcription, translation or typographical errors. For precise and up-to-date information, please contact our company directly.    <\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Some images on this website have been intentionally generated using Artificial Intelligence (AI). This is because, for many applications and projects, it is not possible to disclose photographs of the installation or of the actual system due to confidentiality agreements, confidentiality clauses and non-disclosure agreements (NDAs). <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The Dakota FX70-DL and FX71-DL are portable ultrasonic flaw detectors with A-Scan, B-Scan and dual mode flaw + thickness. A complete solution for field inspections. The Dakota FX70-DL and FX71-DL are ultrasonic flaw detectors in a portable format, designed for field inspections of welds, castings and mechanical components. They combine flaw detection and thickness measurement [&hellip;]<\/p>\n","protected":false},"author":157040980,"featured_media":2188,"parent":2959,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_yoast_wpseo_focuskw":"Dakota FX70-DL","_yoast_wpseo_title":"Dakota FX70-DL \/ FX71-DL: Flaw Detector Portatile | RODER","_yoast_wpseo_metadesc":"Dakota FX70-DL \/ FX71-DL (P\/N Z-221-0005): portable ultrasonic flaw detector for site work, AWS D1.1 weld inspection, DAC and TCG.","_wpcom_ai_launchpad_about_page":false,"_wpcom_ai_launchpad_gallery_page":false,"_wpcom_ai_launchpad_contact_page":false,"_wpcom_ai_launchpad_events_page":false,"_wpcom_ai_launchpad_video_page":false,"_wpcom_ai_launchpad_portfolio_piece":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"footnotes":""},"class_list":["post-2187","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Dakota FX70-DL \/ FX71-DL: Flaw Detector Portatile | RODER<\/title>\n<meta name=\"description\" content=\"Dakota FX70-DL \/ FX71-DL (P\/N Z-221-0005): portable ultrasonic flaw detector for site work, AWS D1.1 weld inspection, DAC and TCG.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Dakota FX70-DL \/ FX71-DL: Flaw Detector Portatile | RODER\" \/>\n<meta property=\"og:description\" content=\"Dakota FX70-DL \/ FX71-DL (P\/N Z-221-0005): portable ultrasonic flaw detector for site work, AWS D1.1 weld inspection, DAC and TCG.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/\" \/>\n<meta property=\"og:site_name\" content=\"ULTRASUONI NDT\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-20T20:10:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?fit=387%2C387&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"387\" \/>\n\t<meta property=\"og:image:height\" content=\"387\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"FAQPage\"],\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/\",\"name\":\"Dakota FX70-DL \\\/ FX71-DL: Flaw Detector Portatile | RODER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?fit=387%2C387&ssl=1\",\"datePublished\":\"2026-06-08T15:21:04+00:00\",\"dateModified\":\"2026-10-20T20:10:01+00:00\",\"description\":\"Dakota FX70-DL \\\/ FX71-DL (P\\\/N Z-221-0005): portable ultrasonic flaw detector for site work, AWS D1.1 weld inspection, DAC and TCG.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#breadcrumb\"},\"mainEntity\":[{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441000000\"},{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441001000\"},{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441002000\"},{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441003000\"},{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441004000\"},{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441005000\"}],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?fit=387%2C387&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?fit=387%2C387&ssl=1\",\"width\":387,\"height\":387,\"caption\":\"Dakota NDT FX70 Flaw Detector hero image for ultrasonic flaw and crack measurement\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Flaw Detectors\",\"item\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Dakota FX70-DL \u2013 Portable Ultrasonic Flaw Detector\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\",\"name\":\"ULTRASUONI NDT\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#organization\",\"name\":\"RODER SRL\",\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/ultrasuonindt.it\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1\",\"width\":1000,\"height\":330,\"caption\":\"RODER SRL\"},\"image\":{\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/roder-srl\"]},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441000000\",\"position\":1,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441000000\",\"name\":\"Has the FX70-DL been replaced by the FX71-DL?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The FX71-DL is the current development of the FX70-DL \\\/ DFX-7 platform with firmware and hardware updates. The Dakota commercial P\\\/N is now Z-221-0005 with the DFX-7+ designation. The features described on this page reflect the current version of the instrument.  \",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441001000\",\"position\":2,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441001000\",\"name\":\"What is the difference between the FX70-DL and the FX81-DL?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The FX70-DL is portable (397 g, 3 \u00d7 AA, 63.5 \u00d7 165 \u00d7 31.5 mm) for field inspections. The &lt;a href=\\\"\\\/prodotti\\\/rilevatori-di-difetti\\\/dakota-fx81-dl-rilevatore-di-difetti-benchtop\\\/\\\">FX81-DL&lt;\\\/a> is a benchtop unit for laboratory or fixed-station inspections, with extended battery life and a larger display. Both share the DFX platform and the detect modes.  \",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441002000\",\"position\":3,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441002000\",\"name\":\"Is it EN 12668-1 compliant?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, the FX70-DL is declared &lt;strong>EN 12668-1 compliant&lt;\\\/strong> by Dakota. EN 12668-1 is the European reference standard for the characterisation and verification of ultrasonic flaw detection equipment and is required for certification in inspections to EN ISO 17640 and similar standards. \",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441003000\",\"position\":4,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441003000\",\"name\":\"Can I also use it as a thickness gauge?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The FX70-DL is a 2-in-1 instrument: configured as a thickness gauge it measures material and coating thickness simultaneously. However, for thickness-only applications we recommend the dedicated gauges in the CMX, MX or PMX ranges, which offer ergonomics optimised for repetitive measurement.  \",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441004000\",\"position\":5,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441004000\",\"name\":\"What is the difference between TRIG and DAC?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"TRIG is a geometric function: it calculates the position and depth of flaws from angle beam probes by applying trigonometry to the beam path. DAC is an amplitude correction function: it creates sensitivity curves against distance in order to classify flaw size. The two are often used together when inspecting welds with angle beam probes.  \",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441005000\",\"position\":6,\"url\":\"https:\\\/\\\/ultrasuonindt.it\\\/en\\\/products\\\/flaw-detectors\\\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\\\/#faq-question-1757441005000\",\"name\":\"Can I store A-Scans together with the measurements?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. With 4 GB of internal memory the FX70-DL stores the A-Scans and B-Scans associated with each measurement in alphanumeric batches. DakMaster\u2122 software makes it possible to review the waveforms in the laboratory for in-depth analysis and to generate professional reports.  \",\"inLanguage\":\"en-US\"},\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Dakota FX70-DL \/ FX71-DL: Flaw Detector Portatile | RODER","description":"Dakota FX70-DL \/ FX71-DL (P\/N Z-221-0005): portable ultrasonic flaw detector for site work, AWS D1.1 weld inspection, DAC and TCG.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/","og_locale":"en_US","og_type":"article","og_title":"Dakota FX70-DL \/ FX71-DL: Flaw Detector Portatile | RODER","og_description":"Dakota FX70-DL \/ FX71-DL (P\/N Z-221-0005): portable ultrasonic flaw detector for site work, AWS D1.1 weld inspection, DAC and TCG.","og_url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/","og_site_name":"ULTRASUONI NDT","article_modified_time":"2026-10-20T20:10:01+00:00","og_image":[{"width":387,"height":387,"url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?fit=387%2C387&ssl=1","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","FAQPage"],"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/","url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/","name":"Dakota FX70-DL \/ FX71-DL: Flaw Detector Portatile | RODER","isPartOf":{"@id":"https:\/\/ultrasuonindt.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#primaryimage"},"image":{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?fit=387%2C387&ssl=1","datePublished":"2026-06-08T15:21:04+00:00","dateModified":"2026-10-20T20:10:01+00:00","description":"Dakota FX70-DL \/ FX71-DL (P\/N Z-221-0005): portable ultrasonic flaw detector for site work, AWS D1.1 weld inspection, DAC and TCG.","breadcrumb":{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#breadcrumb"},"mainEntity":[{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441000000"},{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441001000"},{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441002000"},{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441003000"},{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441004000"},{"@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441005000"}],"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#primaryimage","url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?fit=387%2C387&ssl=1","contentUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-immagine_hero_FX70-Flaw-Detector_per_misure_di_difetti_e_cricche-web-387x387-1.webp?fit=387%2C387&ssl=1","width":387,"height":387,"caption":"Dakota NDT FX70 Flaw Detector hero image for ultrasonic flaw and crack measurement"},{"@type":"BreadcrumbList","@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ultrasuonindt.it\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/ultrasuonindt.it\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Flaw Detectors","item":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/"},{"@type":"ListItem","position":4,"name":"Dakota FX70-DL \u2013 Portable Ultrasonic Flaw Detector"}]},{"@type":"WebSite","@id":"https:\/\/ultrasuonindt.it\/en\/#website","url":"https:\/\/ultrasuonindt.it\/en\/","name":"ULTRASUONI NDT","description":"","publisher":{"@id":"https:\/\/ultrasuonindt.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ultrasuonindt.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ultrasuonindt.it\/en\/#organization","name":"RODER SRL","url":"https:\/\/ultrasuonindt.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ultrasuonindt.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1","contentUrl":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/logo_ultrasuoni_ndt.png?fit=1000%2C330&ssl=1","width":1000,"height":330,"caption":"RODER SRL"},"image":{"@id":"https:\/\/ultrasuonindt.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/roder-srl"]},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441000000","position":1,"url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441000000","name":"Has the FX70-DL been replaced by the FX71-DL?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"The FX71-DL is the current development of the FX70-DL \/ DFX-7 platform with firmware and hardware updates. The Dakota commercial P\/N is now Z-221-0005 with the DFX-7+ designation. The features described on this page reflect the current version of the instrument.  ","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441001000","position":2,"url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441001000","name":"What is the difference between the FX70-DL and the FX81-DL?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"The FX70-DL is portable (397 g, 3 \u00d7 AA, 63.5 \u00d7 165 \u00d7 31.5 mm) for field inspections. The &lt;a href=\"\/prodotti\/rilevatori-di-difetti\/dakota-fx81-dl-rilevatore-di-difetti-benchtop\/\">FX81-DL&lt;\/a> is a benchtop unit for laboratory or fixed-station inspections, with extended battery life and a larger display. Both share the DFX platform and the detect modes.  ","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441002000","position":3,"url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441002000","name":"Is it EN 12668-1 compliant?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Yes, the FX70-DL is declared &lt;strong>EN 12668-1 compliant&lt;\/strong> by Dakota. EN 12668-1 is the European reference standard for the characterisation and verification of ultrasonic flaw detection equipment and is required for certification in inspections to EN ISO 17640 and similar standards. ","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441003000","position":4,"url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441003000","name":"Can I also use it as a thickness gauge?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Yes. The FX70-DL is a 2-in-1 instrument: configured as a thickness gauge it measures material and coating thickness simultaneously. However, for thickness-only applications we recommend the dedicated gauges in the CMX, MX or PMX ranges, which offer ergonomics optimised for repetitive measurement.  ","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441004000","position":5,"url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441004000","name":"What is the difference between TRIG and DAC?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"TRIG is a geometric function: it calculates the position and depth of flaws from angle beam probes by applying trigonometry to the beam path. DAC is an amplitude correction function: it creates sensitivity curves against distance in order to classify flaw size. The two are often used together when inspecting welds with angle beam probes.  ","inLanguage":"en-US"},"inLanguage":"en-US"},{"@type":"Question","@id":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441005000","position":6,"url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/dakota-fx70-dl-portable-ultrasonic-flaw-detector\/#faq-question-1757441005000","name":"Can I store A-Scans together with the measurements?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Yes. With 4 GB of internal memory the FX70-DL stores the A-Scans and B-Scans associated with each measurement in alphanumeric batches. DakMaster\u2122 software makes it possible to review the waveforms in the laboratory for in-depth analysis and to generate professional reports.  ","inLanguage":"en-US"},"inLanguage":"en-US"}]}},"jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/PeHTL3-zh","jetpack-related-posts":[{"id":2959,"url":"https:\/\/ultrasuonindt.it\/en\/products\/flaw-detectors\/","url_meta":{"origin":2187,"position":0},"title":"Flaw Detectors","author":"GSM","date":"16 April 2026","format":false,"excerpt":"FX Series \u2014 Ultrasonic Flaw Detectors Portable for field use Dakota FX70-DL \/ FX71-DL \u2013 Portable Flaw Detector The portable model of the range, optimised for field inspections, hard-to-reach positions and maintenance of in-service components. Part Number Z-221-0005 (designation DFX-7+) Weight 397 g, dimensions 63.5 \u00d7 165 \u00d7 31.5 mm\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Dakota NDT FX70 Flaw Detector ultrasonic family","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":2713,"url":"https:\/\/ultrasuonindt.it\/en\/","url_meta":{"origin":2187,"position":1},"title":"Home","author":"GSM","date":"9 September 2026","format":false,"excerpt":"Check material integrity with ultrasonic technology Thickness gauges, flaw detectors and bolt tension monitors. Product catalogue Contact Product Categories Thickness gauges with A-Scan \/ B-Scan Direct-reading thickness gauges Flaw Detectors Bolt Tension Monitors Special Instruments Probes and Accessories Thickness gauges with A-Scan \/ B-Scan Go to the family \u2192 Dakota\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Dakota NDT family of ultrasonic instruments for thickness and corrosion testing","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=525%2C300 1.5x"},"classes":[]},{"id":2818,"url":"https:\/\/ultrasuonindt.it\/en\/products\/","url_meta":{"origin":2187,"position":2},"title":"Products","author":"GSM","date":"16 April 2026","format":false,"excerpt":"RODER SRL is the official Dakota NDT distributor. The catalogue brings together the full range of ultrasonic instrumentation for non-destructive testing (NDT): thickness gauges for corrosion and precision, flaw detectors, bolt tension monitors, probes and accessories, special instruments for motorsport and data management software. Every instrument is supplied with a\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Dakota NDT family of ultrasonic instruments for thickness and corrosion testing","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=525%2C300 1.5x"},"classes":[]},{"id":14,"url":"https:\/\/ultrasuonindt.it\/prodotti\/rilevatori-di-difetti\/","url_meta":{"origin":2187,"position":3},"title":"Rilevatori di Difetti","author":"GSM","date":"16 April 2026","format":false,"excerpt":"Serie FX \u2014 Rilevatori di Difetti Ultrasonici Portatile da campo Dakota FX70-DL \/ FX71-DL \u2013 Flaw Detector Portatile Il modello portatile della gamma, ottimizzato per ispezioni in campo, posizioni di accesso difficile e manutenzione di componenti in servizio. Part Number Z-221-0005 (denominazione DFX-7+) Peso 397 g, dimensioni 63,5 \u00d7 165\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Famiglia Dakota NDT FX70 Flaw Detector ad ultrasuoni","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia_fx70_flaw_detector_presentazione_famiglia-web-700x700-1.webp?fit=700%2C700&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":6444,"url":"https:\/\/ultrasuonindt.it\/en\/products\/probes-and-accessories\/transducers-for-ultrasonic-flaw-detectors\/","url_meta":{"origin":2187,"position":4},"title":"Transducers for Ultrasonic Flaw Detectors","author":"GSM","date":"6 May 2026","format":false,"excerpt":"Dakota transducers for flaw detectors: shear wave probes (quick change and standard), single element contact, transducer wedges at 45\/60\/70 degrees. For inspecting welds, forgings and composites to AWS, EN ISO and ASME.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Banner presenting transducers for flaw detectors: shear wave probes, single element probes and angle wedges","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/05\/dakota_ndt-trasduttori_flaw-single_element-banner_single_element_2_2-web-387x387-1.webp?fit=387%2C387&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":2711,"url":"https:\/\/ultrasuonindt.it\/home-ultrasuoni-ndt\/","url_meta":{"origin":2187,"position":5},"title":"Home","author":"GSM","date":"9 September 2026","format":false,"excerpt":"Controlla l'integrit\u00e0 dei materiali con la tecnologia ultrasonica Misuratori di spessore, rilevatori di difetti e monitor tensione bulloni. Catalogo prodotti Contatti Categorie di Prodotto Spessimetri con A-Scan \/ B-Scan Spessimetri a lettura diretta Rilevatori di Difetti Monitor Tensione Bulloni Strumenti Speciali Sonde e Accessori Spessimetri con A-Scan \/ B-Scan Vai\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"Famiglia strumenti Dakota NDT ad ultrasuoni per controllo spessore e corrosione","src":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/ultrasuonindt.it\/wp-content\/uploads\/2026\/04\/dakota_ndt-strumenti_di_misura_ad_ultrasuoni-famiglia-di-strumenti_di_misura_ad_ultrasuoni_per_controllo_di_spessore_e_corrosione-web-560x560-1.webp?fit=560%2C560&ssl=1&resize=525%2C300 1.5x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages\/2187","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/users\/157040980"}],"replies":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/comments?post=2187"}],"version-history":[{"count":34,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages\/2187\/revisions"}],"predecessor-version":[{"id":10963,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages\/2187\/revisions\/10963"}],"up":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/pages\/2959"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/media\/2188"}],"wp:attachment":[{"href":"https:\/\/ultrasuonindt.it\/en\/wp-json\/wp\/v2\/media?parent=2187"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}